5-54
EO18-33002A
5. DIAG. TEST OPERATION
5.5 RAM CLEAR MODE
5.5.2 Parameter Clear
Power off
Press the [FEED] key three times.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
< 1
D I A G .
V 1 . O A
>
Turn off the power (NOTE 1)
C O
P L E T E
M
< 4
R A M
C L E A R
>
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [FEED] key twice.
(or press the [RESTART] key twice.)
Press the [PAUSE] key.
N O
R A M
C L E A R
P A
A M E T E R
C L E A R
R
NOTE:
Confirm that “COMPLETE” is displayed, then turn the power off.