5-13
EO18-33002A
5. DIAG. TEST OPERATION
Power off
Press the [FEED] key.
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
[FEED] key:
pressing the [FEED] key one
time is a -0.5 mm change, up to
-20.0 mm. (See NOTE 2.)
< 1
D I A G .
V 1 . O A
>
< 2
P A R A M E T E R
S E T
>
[RESTART] key: pressing the [RESTART] key
one time is a +0.5 mm change,
up to +20.0 mm.
(See NOTE 2.)
Press the [PAUSE] key.
Press the [PAUSE] key.
Press the [PAUSE] key twice.
P O
I T I O N
S
C U
A D J .
+ 0 . 0 m m
T
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Continued on Section 5.3.1. 3
Reverse Feed Distance Fine Adjustment.
Cut position fine adjustment
Position adjustment mode display
NOTES:
1.
Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds
enables a fast forward.
2.
Max. fine adjustment
±
20.0 mm = Key fine adjustment value + PC fine adjustment
value.
When the value reaches the maximum, the value remains unchanged even if a
subsequent fine adjustment is performed.
3.
A changed cut/strip position value is stored in memory by pressing the [PAUSE]
key.
5.3 PARAMETER SETTING MODE