10. MAJOR UNIT REPLACEMENT
EO18-33012A
10.5 RIBBON MOTORS (TAKE-UP, FEED)
10-9
10.5 RIBBON MOTORS (TAKE-UP, FEED)
10.5.1 Ribbon Motor (Take-up)
1) Remove the side panel (L). (Refer to Section 3.2.)
2) Remove the ribbon motor (take-up) harness from CN13 on the Main PC board and the cable
clamp.
3) Remove the two SMW -3x6 screws to detach the ribbon motor (take-up).
CN13
Main PC Board
Cable Clamp
Ribbon Motor (Take-up) Harness
SMW-3x6 Screw
Ribbon Motor (Take-up)