Connector Specifications
6-26
Connector Specifications
DIGITAL CONTROL Connector
<Functions>
Contact input:
REC FWD, REC, FWD, STOP, PAUSE, event, panel lock, internal clock adjustment
Status output:
REC, FWD, STOP, PAUSE, event, panel lock
<Input/Output Circuit>
Input: L level: 0.4 V or less
H level: Open or 2 V or more
Pulse width: 100 ms or more
Output: Open drain, maximum sync current: 8 mA
<Connector>
Angled half pitch 36-pin (DHA-RC36-R1xxx series)
Pin Assignment
Pin No.
Signal
Function
Pin No.
Signal
Function
1 GND
Ground
19 GND
Ground
2 RESERVED
Reserved
20 RESERVED
Reserved
3 RESERVED
Reserved
21 RESERVED
Reserved
4 GND
Ground
22 AGND
Reserved
5 RESERVED
Reserved
23 AGND
Reserved
6 RESERVED
Reserved
24 AGND
Reserved
7 GND
Ground
25 AGND
Reserved
8 RESERVED
Reserved
26 RESERVED
Reserved
9 RESERVED
Reserved
27 RESERVED
Reserved
10 RTCADJIN
Internal clock
adjustment input
28 NC
11
RECFWDIN
REC FWD input
29
NC
12
RECIN
REC input
30
RECSTS
REC output
13
FWDIN
FWD input
31
FWDSTS
FWD output
14
STOPIN
STOP input
32
STOPSTS
STOP output
15
PAUSEIN
PAUSE input
33
PAUSESTS
PAUSE output
16
EVENTIN
EVENT input
34
EVENTSTS
Event output
17
PLOCKIN
Panel Lock input
35
PLOCKSTS
Panel Lock output
18 GND
Ground
36 GND
Ground
For PANEL LOCK input, the control buttons on the front panel of the LX cannot be used to perform operations.
The first signal locks the control buttons; the second signal releases the lock.
100ms or more
Lock Release
1s or more
Содержание LX Series
Страница 2: ......
Страница 10: ...Contents viii...
Страница 26: ...Sampling Frequency and Number of Channels 1 16...
Страница 117: ...Main Unit Specifications 6 3 External Dimensions...
Страница 142: ...Recording Synchronization Specifications 6 28...
Страница 143: ...7 1 Section 7 Appendixes Troubleshooting 7 2 Supplied Accessories and Options 7 3 Supplied Accessories 7 3 Options 7 3...
Страница 146: ...Note 7 4 Note...
Страница 147: ......