409-32023
Rev
B
17 of 41
NOTE
For detailed instructions, refer to Paragraph 2.3, Software Installation.
2. Configure the IP address on the precision controller.
Each precision controller will connect to the machine (TEServerApp application) with a specific and
unique IP address. If there are more than one precision controller in the system, it will be necessary to
configure the IP address of each unit. Additionally, a new precision controller will not be configured
properly to function on a Komax leadmaker. Configure the IP address of each precision controller as
follows:
a. Power up the precision controller.
b. Click the right arrow until the Precision Controller icon is highlighted.
c.
Click the arrow to enter the “IO Interface Page”. See Figure 22.
d.
Click the right arrow to the “Settings Page”. See Figure 22.
Figure 22
If the “Ethernet settings” has an IP address, the Ethernet connection is turned on as shown in
Figure 23. If there is only one precision controller, the configuration is complete.
If the “Ethernet Settings” indicates “please wait ...”, the precision controller is looking for an
automatic setting of the Ethernet address and must be changed. See Figure 23.
Figure 23
IO Interface Page
Settings Page
Ethernet Settings Has IP Address
Ethernet Settings Indicates “Please Wait …”