409-32023
Rev
B
24 of 41
3.2.
Feeder Calibration
1. Power up the controller. At this point, no applicator is connected and the screen will appear as shown
Figure 35
2. Use the Right navigation key to move to the Feeder icon on the main menu bar. See Figure 35.
3. Use the Down navigation key to move to the Calibrate pushbutton. See Figure 36.
4. Press the Enter key to begin the calibration. A progress bar at the bottom of the menu will appear to
indicate this process has begun. See Figure 36.
Figure 36
5. When the feeder has completed its necessary movements, the Apply and Abort pushbuttons will
become visible. Install the calibration gage, and move the feeder by hand until it is in the gage
position. See Figure 37.
NOTE
Use the Up and Down navigation keys to toggle between the “Apply” and “Abort”.
6. When the appropriate pushbutton is highlighted, press the Enter key.
After entering and saving the calibration changes, the screen shown in Figure 37 will appear.
Select OK.
Feeder Icon
Calibrate Pushbutton
Progress Bar