409-32023
Rev
B
35 of 41
NOTE
The feeder may be installed with the terminal strip loaded as shown in Figure 56.
Figure 55
Figure 56
4. Load the applicator (with the feeder attached) into the terminator, and close the guard door.
5. After the feeder is attached, data will be uploaded from or downloaded to the applicator. Removal of
the feeder unit during uploading or downloading data will result in an error and lost data. Therefore,
wait until the "Reading Information from Applicator" message disappears from the display.
The Extend Feed Finger key (shown in Figure 34) must be held until the Feed In Extended Position
indicator (shown in Figure 34) lights before a crimp cycle is triggered.
4.2.
Feeder Calibration
1. Disconnect the feeder from the applicator, and remove the feed finger.
DANGER
To prevent personal injury, keep fingers clear of the feed finger. The next step
will
cause motion.
2. Select "Calibrate" from the Feeder Page screen. When prompted, install the feeder calibration gage.
See Figure 57.
3. Make sure that the gage block (flag) is tight against the side as shown in Figure 57 and tight against
the step of the feeder mounting bracket. Failure to consistently install the feeder block will result in
inaccurate feed position between feed units.
Installing Feeder into Applicator
Feed Finger in Feed Track Groove (Side-Feed Applicator)
Terminal Strip
Downloaded From