12. At this point, the machine will have the smart applicator features installed.
To use the data contained in the smart applicator, it is necessary to configure the terminals to be run
in production properly.
In addition to the terminal name, or mapped terminal, the crimp height and cross section can be
verified as well. This option is enabled by clicking the Config button at the right of the Option editor.
Refer to Figure 17.
Figure 17
These settings affect the operation of all stations. If the smart applicator is checked, the machine will
always check for the applicator, crimp height, and cross section for the installed smart applicator on
the terminator, and display a warning.
When the smart applicator setting is turned on, the machine will always check for a smart applicator
during the verification process prior to entering production. During the verification process, the data
programmed in the machine is compared to the data in the applicator to verify a match.
If "Allow only Smart Applicator data for Crimp Height" is checked or "Allow only Smart Applicator data
for Cross Section" is checked, the machine will not complete the verification process and will not enter
production if there is no smart applicator connected.