19
83532002 Rev H
Local or remote sense may be used. In remote sense, the voltage drop on the load
wires should be minimized. Refer to the Power Supply specifications of Section 2 for
the remote sense maximum voltage drop value.
1.2.8. Cooling and Mechanical Construction
The Genesys
TM
Power Supply Series is cooled by internal fans. During installation, care
must be taken to allow free airflow into the Power Supply via the front panel and out of
the Power Supply via the rear panel.
CAUTION
When an energized load (eg. battery) is connected to the Power Supply
Output always make sure that the Power Supply fans are operating.
Before turning OFF the AC Input power switch, always make sure that the
Output is OFF and the energized load is disconnected from the Output.
See Section 3.9 for details
CAUTION
Observe all torque guidelines within this User’s Manual. Over-torqueing
hardware may damage the unit or accessories. Such damage is not covered
under Manufacturer’s Warranty.
1.3. Accessories
1.3.1. Included Accessories -
The following accessories are
delivered with the Power
Supply.
•
Hardware:
•
AC Input terminal cover
•
Output busbar terminal cover
•
DB25 Programming Plug kit (AMP 749809-9)
(may be optional)
1.3.2. Communication Cables (optional)
•
RS-232 Cables (to connect GEN to Serial Port on PC).
•
RS-485 Cable (to connect GEN to Serial Port on PC).
GEN to PC (DB-9F)
GEN/485-9
P/N: 15-507-202
1.3.3. Serial Link Cable (optional)
•
Cable description: 0.5m length, shielded, RJ45 type plugs, 8 contacts
1.3.4. AC cables – Not applicable.
GEN to PC (DB-9F)
GEN/232-9
P/N: 15-507-203
GEN to PC (DB-25F)
GEN/232-25
P/N: 15-507-204
Serial Link (RJ-45 Type)
GEN/RJ-45
15-507-201