1. Setting up the Master Unit
Master Two-Wire Method
Set the Master unit Output Voltage to the desired voltage. Program the
Master unit Output Current to the desired load current divided by the number
of parallel units. During operation, the Master unit operates in CV mode,
regulating the load voltage at the programmed Output Voltage. Connect the
sensing circuit to local or remote sensing as shown in
Fig. 6-7
or
Fig. 6-8
.
Master Single-Wire Method
Set the Master unit Output Voltage to the desired voltage. Program the
Master unit Output Current to the desired load current divided by the number
of parallel units. During operation, the Master unit operates in CV mode,
regulated the load voltage at the programmed Output Voltage. Connect the
sensing circuit to local or remote sensing as shown in
Fig. 6-9
or
Fig. 6-10
.