83532002 Rev H
2. SPECIFICATIONS
All specifications are subject to change without notice.
Contact factory for specific model availability.
2.1. Output Rating (Duty Cycle Continuous Duty).
2.1.1. Standard Models – 10kW
1. Rated Output voltage
V
7.5
10 12.5 20
25
30
40
50
60
80 100 125 150 200 250 300 400 500 600
2. Rated Output current
A
1000 1000 800 500 400 333 250 200 167 125 100 80
66
50
40
33
25
20
17
3. Rated Output power
kW
7.5 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 9.9 10.0 10.0 9.9 10.0 10.0 10.2
2.1.2. Standard Models – 15kW
1. Rated Output voltage
V
N/A N/A N/A N/A N/A 30
40
50
60
80 100 125 150 200 250 300 400 500 600
2. Rated Output current
A
-
-
-
-
-
500 375 300 250 187.5 150 120 100 75
60
50 37.5 30
25
3. Rated Output power
kW
-
-
-
-
-
15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0
2.2. Input Characteristics
V
7.5
10 12.5 20
25
30
40
50
60
80 100 125 150 200 250 300 400 500 600
1. Input voltage/freq. (range)
---
208VAC (180-253), 400VAC (342-440), 480VAC (432-528), all 47-63Hz
2. # of phases
---
3 Phase (Wye or Delta) 4 wire total (3 Phases and 1 Protective Earth ground)
3. Dropout voltage
V
175/338/425
4. Input current 180/342/432 VAC
A
10kW – 45/23/20, 15kW – 64/32/27; All at full rated Output power.
5. Power Factor (typical)
---
0.88 Passive (208VAC, 400VAC, 480VAC)
6. Efficiency at Low Line, 100% load
%
77 min for 7.5kW, 83 min for 10kW, 88 min for 15kW
7. Inrush current
A
Not to exceed full rated Input current
8. Leakage current
mA
3.5 (EN60950-1) max
9. Input Protection
---
Circuit breaker for 7.5V, 10V and 12.5V Outputs @ 10kW with 208VAC input.
10. Fuse
---
Fuse for: 7.5V, 10V and 12.5V Outputs @ 10kW with 400VAC/480VAC input.
Fuse for: 20V
≤
Vout
≤
600V @ 10kW/15kW with 208VAC/400VAC/480VAC input.
11. Phase Imbalance
%
≤
5% on Three Phase Input
2.3. Static Characteristics
V
7.5
10 12.5 20
25
30
40
50
60
80 100 125 150 200 250 300 400 500 600
1. Max. line regulation, CV
---
0.1% of FS from lo(min) to
lo(max).
0.05% of FS from lo(min) to lo(max).
2. Max. line regulation, CC
---
0.1% of FS from Vo(min) to
Vo(max).
0.05% of FS from lo(min) to lo(max).
3. Max load regulation, CV
---
0.1% of FS from lo(min) to
lo(max).
0.05% of FS lo(min) to lo(max).
4. Max load regulation, CC
---
0.1% of FS from Vo(min) to
Vo(max).
0.075% of FS from Vo(min) to Vo(max).
5. Temperature Stability, CV
---
+/- 0.05% of Vo(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature).
6. Temperature Stability, CC
---
+/- 0.05% of Io(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature).
7. Temperature Coefficient, CV
PPM/C
200 (0.02% of Vo(rated)/Degree C)
8. Temperature Coefficient, CC
PPM/C
300 (0.03% of Io(rated)/Degree C)
9. Output noise p-p (20MHz), CV
mV
60
60
60
60
60
60
60
75
75 100 100 125 150 175 200 200 300 350 350
10. Ripple r.m.s 5Hz
∼
1MHz, CV
mV
20
20
20
20
20
20
20
20
20
25
25
25
25
35
35
60
60
60
60
11. Ripple r.m.s 5Hz
∼
1MHz, CC (10kW)
mA
5300 4000 2560 1000 640 444 250 160 67
50
40
32
26
20
16
13
10
8
7
12. Ripple r.m.s 5Hz
∼
1MHz, CC (15kW)
mA
-
-
-
-
-
350 200 150 100 100 100 50
50
20
20
20
10
10
10
13. Rem.
sense compensation/wire
V
1
1
1
1
1
1.5
2
3
3
4
5
5
5
5
5
5
5
5
5
*Ripple and Noise at Vo(rated) and rated load at 25°C, nominal AC input, per EIJ RC9002A