5.11. Safe Start and Auto-Restart Modes
When turning on the Power Supply, it can start to its last setting of Output voltage and
Output Current limit with the output enabled (Auto-Restart mode) or start with the output
disabled (Safe-Start mode). Press and hold the OUT button to select between Safe-Start
and Auto-Restart modes. The VOLTAGE display will continuously cycle between “SAF”
and “AUT” every 3 seconds. Releasing the OUT pushbutton while one of the modes is
displayed, selects that mode. The default setting at shipment is Safe-Start mode.
5.11.1. Automatic Restart Mode
In this mode, the Power Supply restores its last operation setting. Upon start-up, the
output is enabled or disabled according to its last setting.
5.11.2. Safe Start Mode
In this mode, the Power Supply restores its last operation setting and sets the Output
to the Off state. At start-up, the output is disabled and the Output voltage and Output
current are zero. To enable the output and restore the last Output voltage and current
limit values, momentarily press the OUT button.
5.12. Front Panel Locking
The front panel controls can be locked to protect against an operator accidentally
changing the Power Supply settings.
5.12.1. Changing the Locking
Press and hold the front panel PREView button. The voltage display will toggle
between locked front panel (“LFP”) and unlocked front panel (“UFP”). Select a mode
by releasing the PREView button when the desired mode is displayed.
5.12.2. Unlocked Front Panel
This is the normal operating mode. The front panel controls are able to program and
monitor the Power Supply parameters.
5.12.3. Locked Front Panel
When the front panel is locked, the following controls are
DISABLED
:
•
VOLTAGE and CURRENT encoders.
•
FOLD button.
•
OUT button
The Power Supply will not respond to attempts to use these controls. The VOLT
display will show “LFP” to indicate that the front panel is locked.
Other buttons, such as PREV and OVP/UVL may still be used to view the Power
Supply settings.