Test and Alignment Specification for MT56EP1 Series (v0
01) 160825.docx
Page 12 of 25
Targets
Tolerances
COOL
NORMAL
WARM
ALIGNMENT
MEASUREMENT
Coordinate “x”
Offered by R&D PQ
engineer
± 0.003
± 0.020
Coordinate “y”
± 0.003
± 0.020
Important:
If measurements are performed on whatever else LED panel with Minolta CA210, it’s required to
calibrate additional channel (ex: CH01) using relative following offsets (CH00 remains for CCFL panel):
+0.002
for “
x
”
and
+0.012
for“
y
”.
Note
⑧:
See WB list as follows for more details.
Cloning
Once a TV is well aligned and prepared (channels maps, volume, picture presets, …) , user can prepare golden
clone image that can be copied on demand to all further TV production lot of same TV. To access cloning function, you
can select “
Factory menu
Æ
USB Clone &&Update
Æ
All Clone/CH Clone/User data Clone
” , Scroll down to “
TV to
USB
” or “
USB to TV
” and press RCU “
OK/
►
” key to process. 4 BIN images can created, overwritten or read on USB
stick (pen drive) depending on chosen template like following: “
database\applications\database\***.db
” . These files
need to be used strictly with NT667SoC platform as depending on SW structure.
Other faster access methods via UART/IR commandsare available on enclosed SIACP requirements (rev. v3.9).
2.4. High Pot. and Insulating Resistance Tests
Содержание L32D2930
Страница 45: ...Trouble Shooting No Picture 41...
Страница 46: ...Trouble Shooting No Sound 42...
Страница 47: ...Trouble Shooting Abnormal Picture 43...
Страница 48: ...Trouble Shooting Network Fault wired 44...
Страница 49: ...Trouble Shooting Network Fault wireless 45...
Страница 50: ......