Test and Alignment Specification for MT56EP1 Series (v0
01) 160825.docx
Page 11 of 25
Ensure that TV’spicture enhance is off.
Ensure that TV is in
Factory mode to access to ”
White Balance
” adjustment submenu
, then scroll down to
toggle off “
Pic. Enhance
” flag.
WB Normal is the first mode which is adjusted in HDMI source
,
the next are HDMI warm and cool mode.
Warm
and
Cool
Tone are relatives to
Normal
mode.WB adjust need to fix default G Gain .Offset registers needn’t
to be adjusted.
¾
“
Gain
” registers set need to be adjusted at 70IRE.
Targets and Tolerances for all inputs
(According tocompanyuniform LED color temperature standard of panel)
The measured and adjustable parameters should be mainly “
x
”, “
y
” coordinates.
The White Balance alignment should be performed using a well calibrated and contact less analyzer (ex: Minolta
CA210 or CA310). The analyzer may not touch the screen surface, and measurement must be performed in a dark
environment keeping the probe(s) at 90+/-2° from the panel center.
The results should fulfill specification for each
TV set
offered by R&Dand below tolerances::
NT67
panel name
Energy
FW Min (Nits) Preset Targets (x, y)
Model
Efficient
FW>Min
COOL
NORMAL
WARM
55UA7706
LVU550SE4L CD9W03
A
300
272,290
282,300
312,329