Test and Alignment Specification for MT56EP1 Series (v0
01) 160825.docx
Page 6 of 25
In case of starting from blanked flash, it’s necessary to write “
emmc.upm”
file via factory copy in advance.
OAD Stream
//please delete it ,this mathine did not need this function to update software
To manage quicker mass reflashing on predefined DVB Channel, some licensed IBL tools ('xxx2lli.exe', 'lli2dsm.exe',
dsmmerge.exe …) from Intel byte Inc. might be necessary to create appropriate DVB SSU image. Over some predefine
settings such as repeated data block insertion, null packets size, … that are controllable in configuration file, here below
are mandatory OUI entries structure to prepare DSM-CC carousel image format:
-
export
CUST_OAD_OUI
0x001C50
- export
CUST_OAD_HW_MODEL
0x5395
- export
CUST_OAD_HW_VERSION
0x0000
- export
CUST_OAD_SW_MODEL
0x0001
- export
CUST_OAD_SW_VERSION
0x00
OAD reflashing is managed within 4 steps operation: multiplex detection, DVB transfer, flashing and warm-start.
See Appendix
⑶
“How to upgrade FLASH SWand EEPROM Clone usingOAD”
1.3.
UART & IR Parser
To use both UART and/or IR parser, TV has to be set in Factory mode with itsUSB port well connected to suitable
UART device or an IR emitter device correctly facing up TV (see below “Product Assembly - section 2.0” how to
activate “Factory key”).
The UART parser engine is enabled by sending following command “
0xE2
” from host to TV within following presets
115200
/
8
/
n
/
1
.
Once initialized, “
PS
” caption is toggle displayed on bottom left screen (“S” like Serial).
To communicate with TV depending on SIACP revision layout implementation, you need to fulfill UART/IR
commands protocol and format described on enclosed SIACP requirements document (rev. v3.9).
1.4. Project ID Modification
There aredifferent IDs stored into theeMMC depending on different Panels settings and Models features, but there’s
only one key branching ProjectID that includes all. So, it’s not recommended to modify PaneIDwith Hyper terminal as
other ID features may not change!
To modify ProjectID, you need to go through“
Factory menu
Æ
Other
Æ
Project ID
”, then spin left or right with RCU
“
◄
/
►
” key” keys to suitable ID (Project name is dynamically refreshed).It is necessary to press “OK” key for saving the
setting.
See Appendix
⑷
“
How to changeProjectID with RCU
”
See below is the ProjectID table for reference:
MODEL-EU
ProjectID PanelID
Panel Name
MODEL-EU
ProjectID PanelID
Panel Name
55UA7706 10 10
LVU550SE4L
CD9W03
65UA8696 12 12
AUO_T650QVF05