Test and Alignment Specification for MT56EP1 Series (v0
01) 160825.docx
Page 8 of 25
As SoC as built-in A/D self-calibration mechanism, there’s not any ADC to perform.
1.7. DDC & EDID & T-Link Test
The E-EDID data structures are according to VESA Enhanced EDID 1.3 (and EIA/CEA-861B for HDMI). CEA Timing
Extension structure has been extended to support all 3D capable timings.
All HDMI structures have their own BIN profile which are part of main SW and uploaded at power-on into soc chipset:
For EDID check, it’s needed to check whether the correct EDID is downloaded by checking corresponding EDID
NVM Checksum or read them out to check bit by bit if it is in line with the released EDID bin file.
1.8. HDCP Test
For HDCP compliancy, it’s needed to check whether the HDCP key has been well set by connecting suitable
generator.
1.9 CI+Key Upgrade, Activation and Test
See Appendix
⑹
“
How to upgradeCI Key using USB
”
1.10. LAN and WLAN Test(MAC address and Device/User ID codes)
Here are some representative codes examples:
MAC Address Upgrade (IPv6)
MAC can be set using UART commands described on enclosed SIACP requirements (rev. v3.9).
- Writing MAC command <
0xB3
>, Data length <
6
>, Data type <
HEXA
> (see below command example from above
MAC code)
<
AA 0B B3
00 1C 50 E2 B1 EC
36 78
>
See Appendix
⑺
“
How to upgradeMAC Address using USB
”
DeviceID (DID)
Purpose is to allow Other Newtork Download (OND) and further specific Services via dedicated abroad portal (UK
tbc).4 At final, when TV may ask for portal connection, there’ll be Device ID matching control sent by host (TV client)
to ensure total integrity.
Device ID
User ID
MAC Address
6fa0806936a0ada733262a3f8e8595d5586ce5cb
111382090
00:1C:50:E2:B1:EC
Содержание L32D2930
Страница 45: ...Trouble Shooting No Picture 41...
Страница 46: ...Trouble Shooting No Sound 42...
Страница 47: ...Trouble Shooting Abnormal Picture 43...
Страница 48: ...Trouble Shooting Network Fault wired 44...