Page | 110
Event
Code
Algorithm
Description
Check/
Alert
---
n/a
All OK
n/a
S01
n/a
No Sensor Connected
– Please Connect the Sensor.
A
S02
n/a
Sensor Not Configured
– Configure the Sensor via CADS.
A
S03
n/a
Display Not Configured
– Configure the Display via Insight
A
S04
n/a
New Sensor Detected
n/a
E01
Current Temperature >= Temp High Warning Level
Oil Temperature High
– Check Regularly.
C
E02
Current Temperature >= Temp High Alarm Level
Oil Temperature Very High
– Immediate Action Required.
A
E03
Current Temperature <= Temp Low Warning Level
Oil Temperature Low
– Check Regularly.
C
E04
Current Temperature <= Temp Low Alarm Level
Oil Temperature Very Low
– Immediate Action Required.
A
E05
Current Oil Condition >= Oil Condition High Warning Level
Oil Condition Too High
– Check Regularly.
C
E06
Current Oil Condition >= Oil Condition High Alarm Level
Oil Condition Very High
– Immediate Action Required.
A
E07
Current Oil Condition <= Oil Condition Low Warning Level
Oil Near End Of Life
– Check Regularly.
C
E08
Current Oil Condition <= Oil Condition Low Alarm Level
Oil At End Of Life
– Immediate Action Required.
A
E09
Current Oil Condition >= 1200 TDN
Sensor In Air
– Immediate Action Required
A
E11
Long Term +ve Decay Rate Warning (TDN/day)
Oil Quality degrading faster than expected
– Check
Regularly.
C
E12
Long Term +ve Decay Rate Alarm (TDN/day)
Oil Quality degrading much faster than expected
–
Immediate Action Required.
A
E13
Long Term -ve Decay Rate Warning (TDN/day)
Oil Quality improving faster than expected - Check
Regularly.
C
E14
Long Term -ve Decay Rate Alarm (TDN/day)
Oil Quality improving much faster than expected -
Immediate Action Required.
A
E15
Short Term +ve Decay Rate Warning (TDN/day)
Oil Quality degrading faster than expected - Possible
Water/Coolant Contamination - Check Regularly.
C
E16
Short Term +ve Decay Rate Alarm (TDN/day)
Oil Quality degrading much faster than expected
– Highly
Likely Water/Coolant Contamination - Immediate Action
Required.
A
E17
Short Term -ve Decay Rate Warning (TDN/day)
Oil Quality improved - Suspected oil top up / sweetening -
Check Regularly
C
E18
Short Term -ve Decay Rate Alarm (TDN/day)
Oil Quality improved too much - Suspected Air or severe
fluid contamination - Immediate Action Required.
A
Figure 75 - Data Logic Table
12.3
Advanced Fault Detection (AFD)
Advanced fault detection is the identification of potential issues in a piece of machinery that
present themselves as a fault or anomaly in the oil condition. As the Oil Quality Sensor sends
back a holistic full spectrum analysis of the oil condition in the form of a condition number
(TDN or %LF), the trend of these returned numbers can be analysed to identify an emerging
issue or concern, which may require further investigation or rectification.
By downloading and interrogating data collected by the sensor, it is possible to identify
different types of degradation of the oil, including water ingress, wear metals, TBN decrease
and soot increase.
Water and wear metals have very distinct characteristics and are therefore very easy to
identify. Whereas with TBN decrease (TAN increase) and soot, during the very early stages of
Содержание OQSExISG2
Страница 1: ...UG OQSxG2 23 0025 OIL QUALITY SENSOR ASSOCIATED ACCESSORIES USER GUIDE...
Страница 2: ......
Страница 5: ...Page 3 Page Intentionally Blank...
Страница 37: ...Page 35 Figure 19 Connection to other Tan Delta and 3rd Party Products Interfaces...
Страница 38: ...Page 36 Figure 20 ExOQSxG2 Ex Sensor Installation Drawing Rev 2 STAMPED...
Страница 42: ...Page 40 8 Display Express...
Страница 97: ...Page 95 P4 CANL RS485A P5 0V P6 CANH RS485B...