Page | 79
Bitrate:
object (specific entry
–
read only,
fixed 125kbit/s
)
Number of PDOs:
PDO1 synchronous or asynchronous configurable
Emergency message:
supported
Node Guarding:
supported
Device Profile:
DS404
11.2.4.2
Object Dictionary Communication Profile
Index
(HEX)
Sub
Index
Name
Type
Access Default
Comment
1000
00
Device Type
U32
RO
0x000E0194
DSP404 analog output,
input & digital output
1001
00
Error Register
U8
RO
0x00
Error Register definition (index 0x1001); 0 = no error, 1 = error:
B0:
Global Error
B1:
unused
B2:
unused
B3:
Temperature Error
B4:
CAN Communication Error
B5:
Oil Quality Error
B6:
unused
B7:
unused
Index
(HEX)
Sub
Index Name
Type
Access Default
Comment
1005
00
COB-ID SYNC
U32
RO
0x80
1008
00
Manufacturer Device Name
VIS STR RO
“Oil Quality Sensor”
Sales Code
1009
00
Manufacturer Hardware Version VIS STR RO
“V19”
Build Version
100A
00
Manufacturer Software Version VIS STR RO
“3.101”
Software Version
100C
00
Guard Time
U16
RO
20000
100D
00
Life Factor
U16
RO
1
1018
Identity Object
00
Number of entries
U8
RO
0x4
01
Vendor ID
U32
RO
0x32F
Vendor ID
02
Product Code
U32
RO
111021
Sales Code
03
Revision No.
U32
RO
0900
04
Serial No.
U32
RO
S/No.
Содержание OQSExISG2
Страница 1: ...UG OQSxG2 23 0025 OIL QUALITY SENSOR ASSOCIATED ACCESSORIES USER GUIDE...
Страница 2: ......
Страница 5: ...Page 3 Page Intentionally Blank...
Страница 37: ...Page 35 Figure 19 Connection to other Tan Delta and 3rd Party Products Interfaces...
Страница 38: ...Page 36 Figure 20 ExOQSxG2 Ex Sensor Installation Drawing Rev 2 STAMPED...
Страница 42: ...Page 40 8 Display Express...
Страница 97: ...Page 95 P4 CANL RS485A P5 0V P6 CANH RS485B...