Product Specifications
AUTOLOADER LTO3 – User Reference Manual Rev. 1.01
TANDBERG DATA
Page 6 9 of 79
12.3 Power Specifications
AC Power
The autoloader has automatic AC input voltage selection and accepts the input voltages shown in the
following table. It is capable of continuous operation when the AC power experiences intermittent
operation, voltage surges, and voltage spikes.
Input voltage
100 to 240 V AC ±10%, 50 to 60 Hz
Power consumption
Average while idle
Average while operating
Maximum while operating
Average heat output while
operating
1)
20 watts
35 watts
48 watts
TBD
Table 13
AC power specifications
1) Based on the AC true power consumption.
AC Power Cord
The autoloader is shipped with a 7-foot (2.1-meter), three-conductor, 18 AWG power cord for 120 volt
use in the United States and Canada. The power cord has a molded NEMA 5 -15P male connector on
one end and a molded IEC 320/EN 60320 female connector on the other end. The power cord is UL
Listed and CSA Certified.
If you plan to use other input voltages or use the autoloader outside of the United States or Canada,
you must supply a power cord that meets the following specifications.
United States and Canada 220 V AC power cord
n
The power cord must have a molded NEMA 6-15P attachmen t plug on one end.
n
The power cord must have a molded EC 320/EN 60320 female connector on the other end.
n
The cordage must be an SJT or SVT type, 3-conductor, 18 AWG minimum.
n
The power cord must comply with local electrical code.
International 230 V AC power cord
n
The power cord must have a grounded attachment plug of the proper type, rating, and safety
approval for the intended country.
n
The power cord must have an IEC 320/EN60320 female connector on one end.
n
The cordage must be harmonized to CENELEC publicati on HD-21. The electrical characteristics
and rating must be minimum H05VVF3G0.75 (6 A).