Troubleshooting and Diagnostics
Error
Messages and Error Codes
AUTOLOADER LTO3 – User Reference Manual Rev. 1.01
TANDBERG DATA
Page 4 8 of 79
9.4.10 Robotic Control Errors 81h – 8Fh
Error Code
Description
Recommended Action
81h
Invalid internal command error.
This error indicates that the robotic
received an undefined internal command
or an invalid parameter to a command.
Retry operation, after several
occurrence contact Technical
Support
82h
Device status not suitable to execute this
command.
If the robotic is busy, some commands
can’t be executed at the same time. This
error will indicate a probable conflict. This
is not an error condition, but does result in
reporting busy condition to the host for the
requested SCSI command.
Retry operation, after several
occurrence contact Technical
Support
83h
Inventory not valid.
The cartridge inventory is not valid,
because of manual changes or previous
fatal errors.
Perform an inventory rescan
(menu item COMMANDS/RE -
INVENTORY)
84h
Source element not ready.
Transport source element has not the
expected state.
Perform an inventory rescan
(menu item COMMANDS/RE -
INVENTORY)
85h
Destination element not ready.
Transport destination element has not the
expected state.
Perform an inventory rescan
(menu item COMMANDS/RE -
INVENTORY)
86h
Assigned to a rejected user attempt to
access door while media removal is
prevented.
Finish IMPORT/EXPORT,
afterwards retry operation
87h
Is used for several robotic command
timeout conditions.
Reset the unit (menu item
CONFIGURATION/RESET)
89h
Timeout detected by loader on system
testing
Reset the unit (menu item
CONFIG URATION/RESET),
restart System Test
8Fh
No error after loader recovery.
Only informational message, no
action required