Installation and Setup
Running Library
Verify Test
AUTOLOADER LTO3 – User Reference Manual Rev. 1.01
TANDBERG DATA
Page 2 8 of 79
7.4.5 Connecting Power
1. Connect the PCC cable (included with your rack mount kit) to the rear of the autoloader.
2. Connect the other end of the PCC cable to your rack’s power strip.
3. Power on the power strip.
4. Power on the autoloader.
The autoloader will verify the drive configuration and status, build a valid cartridge inventory log, and
calibrate the robotic cartridge loader.
The OCP’s green READY/ACTIVITY LED (light -emitting diode) will blink during this initialization
process.
When the autoloader completes the Power-On Self Test (POST) for the dri ve and the library, the
green READY/ACTIVITY LED will stop blinking.
The autoloader will be in automatic mode (the default mode) and SEQ will appear in the lower right
corner of the OCP display.
For information about the autoloader’s modes of operation, see ThinStor
®
Plus LTO3 Autoloader –
Operator's Manual. If a failure occurred, the red ERROR LED will light up and an error message will
be displayed on the OCP. See Troubleshooting and Diagnostics on page 40.
5. If the power on is successful, run the Library Verify test (see Running Library Verify Test on
page 28).
7.5 Running Library Verify Test
1. Press
Enter
on the OCP at the ONLINE screen.
2. Press
Next
four times to navigate to the Diagnostic Menu.
3. Press
Enter
to navigate to the LOADER DIAG menu item.
4. Press
Enter
to access LIBRARY VERIFY.
5. Press
Enter
to begin the verification.
6. On the OCP display, you will be asked to insert a cartridge.
7. When the I/O Door opens, insert a blank cartridge or a scratch cartridge.
The I/O Door will close automatically.
While the test is running, the OCP will display library status.
8. If the test PASSED, proceed to the next step.
9. If the test FAILED, see Determining a Problem on page 41.
10. Press
Enter
.
11. When prompted by the OCP display, remove the cartridge.
12. Press
Enter
to end the test.
13. Power off the autoloader.