19
Instructions
for
use
of
the
machine
–
section
k
in
this
manual
Instructions
about
adjustment
and
maintenance
–
section
r
in
this
manual
Safety
during
adjustment
and
maintenance
–
section
s
f.
Employees
in
charge
of
operation/control/maintenance
After
start
‐
up
and
hand
‐
over
from
installer
to
operators,
the
unit
operates
fully
automatically.
Indications
of
operating
status
as
well
as
indication
of
faults
are
visible
in
a
display
and
on
LEDs
at
a
hand
terminal.
The
operators
can
enter
new
parameters
in
a
controller
via
buttons
on
a
hand
terminal.
Alternatively,
the
controller
can
be
connected
to
a
BMS
system
so
that
new
parameters
can
be
selected
via
PC,
tablet
or
Smartphone.
The
operators
do
not
need
to
open
inspections
doors
for
the
operation
Skilled
technicians
must
carry
out
maintenance
as
well
as
repairs.
g.
Intended
use
and
range
of
applications
The
air
handling
units
are
intended
for
the
transport
and
treatment
of
air
between
‐
40
°C
and
+
40
°C
The
units
are
exclusively
for
comfort
ventilation.
The
units
are
not
for
environments
that
exceed
the
corrosion
class
C4
according
to
EN
ISO
12944
‐
2.
Intended
applications
for
the
units
are:
Offices,
teaching
rooms,
hotels,
shops,
homes
and
similar
comfort
zones.
h.
Unintended
use
and
misuse
–
inappropriate
applications
for
the
machine
Units
for
outdoor
installation
must
be
specified
and
ordered
for
outdoor
installation.
The
units
must
not
be
used
in
environments
that
exceed
corrosion
class
C4
according
to
EN
ISO
12944
‐
2,
and
for
transport
of
solid
particles.
Examples
of
not
intended
use:
Kitchen
extraction,
swimming
pools,
off
‐
shore,
Ex
‐
areas,
drying
of
washed
clothes.
Do
not
use
the
unit
with
partly
finished
duct
systems.
Do
not
use
the
unit
for
ventilation
of
the
building
site
until
the
unit
is
properly
provided
with
guards.
h.1
Air
handling
unit
in
operation
The
pressure
difference
between
interior
and
exterior
of
the
unit
must
not
exceed
2000
Pa
for
the
DV
10
and
up
to
DV
150
(including
DV
150),
and
1500
Pa
for
DV
190
and
DV
240.
Before
start
‐
up
of
the
unit
all
ducts,
safety
guards
and
all
protective
devices
must
be
mounted
to
prevent
any
access
to
rotating
fan
impellers.
All
inspection
doors
must
be
closed
and
locked
when
the
unit
is
in
operation.
Do
not
use
the
unit
without
filters.
Содержание Danvent DV-10
Страница 16: ...15 DVE Plug fan DVD Silencer DVX Humidifier...
Страница 57: ...56...
Страница 58: ...57 Annex for the User Manual Air Handling Units Danvent DV Without control system Version 1 01 13...
Страница 84: ...8 8...
Страница 88: ...9 4 9 1 3 Information about connection of cables to terminals on the control board...
Страница 91: ...9 7...
Страница 92: ...9 8 A1 Size Quantity Length mm DV 60 4 1014 DV 80 4 1164 DV 100 4 1314 DV 120 4 1464 DV 150 4 1614 A1...
Страница 94: ...9 10 9 3 Assemble divided rotor from Hoval Enventus for DV 60 DV 80 and DV 100 9 3 1 Tools and aids 0 100Nm 3 3...
Страница 103: ...9 19...
Страница 111: ...12 3...
Страница 115: ...12 7 Frequency converter is always necessary for the control of each PM motor...
Страница 119: ...13 1 Annex 13 Commissioning See separate cover with annexes 1 2 3 and 13...