ELECTRIC HEATING UNITS 

LM20031   B

INSTALLATION GUIDE 

GENERAL

 

The  EFM  /  ELB  Series  unit  is  designed  for

 

permanent 

upflow,

 

counterflow,

 

or

 

horizontal  left/right  airflow 

installation.    Optional  DX  coils  are  available  tha

t which 

allows

  for  add  on 

of 

DX  air  conditioning  and  heat  pump 

applications to meet specific requirements of the outdoor 
equipment.  The EFM / ELB Series  are

 

available

 

in  sev-

eral  models  ranging  from  600  CFM  to  2000  CFM  of  air 
movement.    Electric  resistance  heat  is  available  from 
3 to 20 KW. 

Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any 
other local codes or utilities requirements. 

UNPACKING

 

Carefully  unpack  the  unit  and  inspect  the  contents  for 
damage.  If any damage is found at the time of delivery 
proper  notification  and  claims  should  be  made  with  the 
carrier who delivered the unit. 

Check the unit  rating plate to insure model  number and 
voltage, plus any kits agree with what you ordered.  The 
supplier  should  be  notified  immediately  of  any 
discrepancy or parts shortage. 

LOCATION

 

The blower coil unit should be centrally located and may 
be installed in 

an attic, basement or crawl space with 0” 

clearance from any side, front, rear or duct work 

If  the  unit  is  located  above  a  finished  ceiling  or 
space,  an  auxiliary  safety  drain  pan  must  be 
installed  under  the  unit.  A  separate drain line  must 
be installed from the safety pan. 

WARNING:

 

Due  to  possible  damage  to  equipment  or  personal  injury,  installation,  service  and 

maintenance  should  only  be  performed  by  a  trained,  qualified  person.    Consumer  service  is  recommended 
only for filter replacement. 

WARNING:

 

HAZARDOUS  VOLTAGE 

–  Ensure  all  power  is  disconnected  before  installing  or  servicing 

this unit.  More than one disconnect device may be required to de-energize the equipment.  Hazardous voltage 
can cause severe personal injury.  Make certain all panels are in place before operating this unit.

 