EFM / ELB
SERIES
ELECTRIC HEATING UNITS
LM20031 B
INSTALLATION GUIDE
GENERAL
The EFM / ELB Series unit is designed for
permanent
upflow,
counterflow,
or
horizontal left/right airflow
installation. Optional DX coils are available tha
t which
allows
for add on
of
DX air conditioning and heat pump
applications to meet specific requirements of the outdoor
equipment. The EFM / ELB Series are
available
in sev-
eral models ranging from 600 CFM to 2000 CFM of air
movement. Electric resistance heat is available from
3 to 20 KW.
Installation of this unit shall be made in accordance with the National Electric Code, NFPA No. 90A and 90B, and any
other local codes or utilities requirements.
UNPACKING
Carefully unpack the unit and inspect the contents for
damage. If any damage is found at the time of delivery
proper notification and claims should be made with the
carrier who delivered the unit.
Check the unit rating plate to insure model number and
voltage, plus any kits agree with what you ordered. The
supplier should be notified immediately of any
discrepancy or parts shortage.
LOCATION
The blower coil unit should be centrally located and may
be installed in
an attic, basement or crawl space with 0”
clearance from any side, front, rear or duct work
If the unit is located above a finished ceiling or
space, an auxiliary safety drain pan must be
installed under the unit. A separate drain line must
be installed from the safety pan.
WARNING:
Due to possible damage to equipment or personal injury, installation, service and
maintenance should only be performed by a trained, qualified person. Consumer service is recommended
only for filter replacement.
WARNING:
HAZARDOUS VOLTAGE
– Ensure all power is disconnected before installing or servicing
this unit. More than one disconnect device may be required to de-energize the equipment. Hazardous voltage
can cause severe personal injury. Make certain all panels are in place before operating this unit.