36
If
a
person
is
hit
by
a
unit
that
is
dropped,
this
could
in
unfortunate
circumstances
lead
to
irreversible
injury
or
death.
Claim
for
reduction
of
danger:
Correct
handling
during
transportation
is
described
in
this
manual.
If
lifted
by
fork
‐
lift
truck
the
forks
of
the
truck
must
be
sufficiently
long.
Safety
measures
are
also
described
in
this
manual
by
use
of
crane.
Information
about
weight
of
each
section
is
also
visible.
l.2
Common
for
all
unit
sections
l.2.1
Risk
caused
by
surfaces,
edges
and
corners
Hazards/dangerous
area:
Sharp
edges
on
plates
might
occur
inside
the
machines
as
well
as
sharp
edges
on
frames
of
dampers.
No
sharp
edges
on
the
outside
of
the
units.
Dangerous
incident:
Cut
fingers/hands.
Claim
for
reduction
of
danger:
Risk
only
exists
during
maintenance
and
cleaning.
This
takes
place
at
least
once
every
year.
Use
of
gloves
and
helmet
is
described
in
this
manual.
Cut
‐
resistant
gloves
for
protection
against
injury
from
sharp
metal
plate
edges.
Use
CE
‐
marked
gloves
for
this
purpose.
Lamps
mounted
inside
the
unit
with
sufficient
lighting
reduce
the
risk
of
injury.
l.3
Common
for
all
unit
sections
by
insufficient
lighting
l.3.1
Risk
caused
by
insufficient
lighting
inside
sections
Hazards/dangerous
area:
On
the
floors
of
the
units
there
are
handles
to
hold
filters,
profiles
for
the
carrying
of
fan
motors.
Cables
are
between
fan
motors
and
frequency
converters.
Dangerous
incident:
By
insufficient
lighting,
the
above
‐
mentioned
obstacles
are
not
visible
with
the
risk
of
stumbling
that
becomes
a
fall,
leading
in
unfortunate
circumstances
to
irreversible
injury
or
death.
Claim
for
reduction
of
danger:
Risk
only
exists
during
maintenance
and
cleaning.
This
takes
place
at
least
once
every
year.
According
to
this
manual
and
in
the
SystemairCAD
software
for
configuration
and
selection
of
accessories,
lamps
for
sufficient
lighting
inside
the
units
are
mandatory
according
to
the
latest
interpretations
of
the
Machinery
Directive
by
the
authorities.
Use
of
helmets
reduces
the
risk
of
injury.
l.4
Dampers
type
DVA
–
DVB
–
DVM
–
DVP
–
Bypass
dampers
in
DVQ
l.4.1
Risk
caused
by
maintenance
and
cleaning
of
dampers
Hazards/dangerous
area:
Are
between
the
damper
blades
and
the
system
of
bars
and
links
between
motor
and
damper
blades.
Dangerous
incident:
Crushing
of
fingers.
Claim
for
reduction
of
danger:
Examination
is
still
under
preparation
in
our
own
laboratory.
Still
no
voluntary
test
persons
are
available.
l.5
Attenuators
type
DVD
Содержание Danvent DV-10
Страница 16: ...15 DVE Plug fan DVD Silencer DVX Humidifier...
Страница 57: ...56...
Страница 58: ...57 Annex for the User Manual Air Handling Units Danvent DV Without control system Version 1 01 13...
Страница 84: ...8 8...
Страница 88: ...9 4 9 1 3 Information about connection of cables to terminals on the control board...
Страница 91: ...9 7...
Страница 92: ...9 8 A1 Size Quantity Length mm DV 60 4 1014 DV 80 4 1164 DV 100 4 1314 DV 120 4 1464 DV 150 4 1614 A1...
Страница 94: ...9 10 9 3 Assemble divided rotor from Hoval Enventus for DV 60 DV 80 and DV 100 9 3 1 Tools and aids 0 100Nm 3 3...
Страница 103: ...9 19...
Страница 111: ...12 3...
Страница 115: ...12 7 Frequency converter is always necessary for the control of each PM motor...
Страница 119: ...13 1 Annex 13 Commissioning See separate cover with annexes 1 2 3 and 13...