5.2 “Manufacturer defined”
objects relating to the
individual axes
Among the objects defined by System Spa for axes
ETC840/QUAD actually implements only those contained
in the following table (relative to axis 1 only); others,
although defined, are used mostly for production testing
and are not of interest to the user.
Table 5.2.1
NOTES
(1) See Tables 5.2.2 and 5.2.3.
(2) If the flag ppParmsChangeOnNewSetpoint is
TRUE and the axis is in pp mode, all the kinematic
parameters are actually activated only on the
positive edge of the NewSetpoint flag contained
in the ControlWord (not only the parameter
TargetPosition).
(3) The T
i
temperatures are not rigidly associated
to the i-th axis; T1 and T2 are two temperatures
read inside the only dissipator associated to axes 1
and 2; T3 and T4 are two temperatures read inside
the only dissipator associated to axes 3 and 4.
(4) These flags allow to thoroughly monitor the
work of the axis power section and identify any
faults more easily.
In particular, the presence and correct wiring of
the motor in the start-up stage is checked, after
motor enabling; if the motor is not connected or
is connected incorrectly, the axis starts to fail. See
Table 5.2.4 for a detailed description.
(5) Bit 15 of this auxiliary ControlWord enables
the interpretation of the three less significant
bits as follows: bit 0 indicates if the axis is in the
acceleration ramp, bit 1 if it is moving at constant
speed and bit 2 if it is in the deceleration ramp.
This information allows an appropriate setting of
the motor current when the axis is in csv mode;
when the axis is in pp mode (trapezoidal or S-
Curve positioning), the drive shall manage the
current independently in the most appropriate
way.
(6) 0=1/256; 1=1/128; … ; 7=1/2; 8=1/1 (full
step).
Table 5.2.2 Configuration of digital inputs as limit switches
Table 5.2.3 Digital inputs used as limit switches
Table 5.2.4
Index
Name
Bit
size Type Min Max Default R/W
0x2000 Configuration Miscellanea
6
rw
Sub 1: Nominal current [0.1A]
8 USINT 1
130
30
rw
Sub 2: Reduced current [0.1A]
8 USINT 1
130
rw
10
Sub 3: Boost current [0.1A]
8
USINT 1
130
rw
Sub 4: Voltage Low Threshold [V]
50
8
USINT 0
180
25
rw
Sub 5: Voltage High Threshold [V]
8 USINT 0
180
180
rw
Sub 6: Temperature Threshold [°C] 8 USINT 0
90
90
rw
0x2003 Positive Limit
(1)
3
rw
Sub 1: Present
8 USINT
0
rw
Sub 2: Signal Level
8 USINT
0
rw
Sub 3: Event action
8 USINT
0
rw
0x2004 Negative Limit
(1)
3
rw
Sub 1: Present
8 USINT
0
rw
Sub 2: Signal Level
8 USINT
0
rw
Sub 3: Event action
8
USINT
0
rw
0x200F Special Setting
1
rw
Sub 1: pp Parms change
on NewSetpoint
(2)
8
0x2010 Analog Data
3
ro
Sub 1: Actual Current [0.1A]
USINT
8
0
ro
Sub 2: Temperature [0.1]
(3)
8
SINT
0
ro
Sub 3: Voltage [V]
USINT
8
0
ro
0x20FD Status Flags
(4)
32 UDINT
ro
0x20FC Aux Control Word
(5)
16 UINT
0
rw
0x2402 Microstepping Resolution
(6)
16 UINT
rw
0x2700 Start Velocity
32 UDINT
0
rw
USINT
0
rw
0x2001 Motor rated current [0.1A]
8 USINT 1
100
100
rw
Subindex
Name
01
Present
Indicates if the limit switch
is present (=1)
or not present (=0)
02
Signal Level
Signal polarity
0=negative, 1=positive
03
Event Action
the actions listed
on the right are
carried out following
the excitement
of limit switches
0 = None
1 = Reserved (do not use)
2 = Abrupt Stop
3 = Smooth Stop
Input 1
Negative Limit Axis1
Input 2
Positive Limit Axis1
Input 5
Negative Limit Axis2
Input 6
Positive Limit Axis2
Input 9
Negative Limit Axis3
Input 10
Positive Limit Axis3
Input 13
Negative Limit Axis4
Input 14
Positive Limit Axis4
Bitmask
position
Short name
Description
0x0000000FUL
STSFLAG_Reserved
Reserved
0x00000010UL
STSFLAG_DontCare
Reserved
0x00000020UL
STSFLAG_AtFullStep
Indicates whether the motor is in FullStep
(therefore with a phase at 100% of the
maximum current set and the other one at 0A)
0x00000040UL
STSFLAG_AxisActive
Indicates whether the axis is active and in a pair
0x00000080UL STSFLAG_CurrentRegulated
Indicates whether the current set has been
reached. Typically is the motor rotation speed
is not high and the current is low, the flag is
present during all motor motion. If the speed
is too high as well as the set-point current, the
CurrentRegulated signal is hardly ever present,
the form of the supplied current, if measured,
takes on cuspidale forms. There may be
different easons for which the current is not
reaches, for example excessive resistance
in the motor connection
0x00000100UL
STSFLAG_Fail_LA
Phase A left branch error
0x00000200UL
STSFLAG_Fail_RA
Phase A right branch error
0x00000400UL
STSFLAG_Fail_LB
Phase B left branch error
0x00000800UL
STSFLAG_Fail_RB
Phase B right branch error
0x00001000UL
STSFLAG_OverCurrent
Overcurrent time-averaged
0x00002000UL
STSFLAG_ClockFail
Synchronisation error with the current branch
sensor indicated by STSFLAG_Fail_# #
Typically this error occurs if the motor is
not connected or if a phase is defective
0x00004000UL STSFLAG_FastOvercurrent
Instantaneous overcurrent: the fail may occur
in the event of significant current variations
(even when switching from minimum to
maximum current, depending on the power
supply-cable conditions and inductance of
the motors used)
0x00008000UL
STSFLAG_OverVoltage
Overcurrent (for the pair of associated
axes 1-2/3-4)
Axis 1 and axis 2 share the same power supply
Axis 3 and axis 4 share the same power supply