Deploying the 7100 Series
Deployment options
Figure 3-5
4 In-line Bypass unit
Port groups and the management port on the bypass unit
Each bypass unit contains groups of ports called port groups. Each port group
contains four ports that connect to the network and to the in-line pair ports on
the appliance.
Each bypass unit also has a USB port for communication with the appliance.
The Net A port of each port group on the bypass unit is implemented as
10/100/1000Base-TX. It is a Medium Dependent Interface, crossed (MDIX). You
may need a crossover cable to connect Net A to some devices. The Net B port of
each port group is implemented as 10/100/1000Base-T (MDI). Consult the
documentation for your network devices to determine whether they require
crossover connections.
You must supply at least four connections to each port group in use on the
bypass unit, plus one USB connection per bypass unit.
Table 3-3
describes these
connections.
Table 3-3
Connections needed for deploying bypass unit
Connection
Bypass port Description
The appliance USB
port
Mgmt USB
Connects to either USB port on the appliance. The
two devices communicate over the USB
connection.
One side of the
network
Net A
Connects to one side of the network that you are
protecting. Net A is the Base-TX port (MDIX).
1 - Serial port
2 - Mgmt USB
3 - Power Supply 1
4 - Power Supply 2
5 - Port group 0
6 - Port group 1
7 - Port group 2
8 - Port group 3
Содержание 10521148 - Network Security 7161
Страница 1: ...Symantec Network Security 7100 Series Implementation Guide...
Страница 8: ...8...
Страница 16: ...8 Contents...
Страница 24: ...16 Introduction Verifying the materials...
Страница 52: ...44 Deploying the 7100 Series Symantec LiveUpdate accessibility...
Страница 174: ...166 Maintaining and administering the 7100 Series Using the serial console...
Страница 190: ...182 Re imaging and unconfiguring About migration...
Страница 198: ...190 Specifications and safety Product certifications...
Страница 214: ...12 Index...