178 Re-imaging and unconfiguring
Re-imaging the appliance
2
Connect a second Ethernet cable from the left-most, top, RJ45 port (port 0)
on the 7160 to the hub or switch.
Note:
If you use a switch, configure it so that the two ports can pass network
traffic between them.
3
Confirm that the link light is lit for port 0 on the 7160, and on the Imaging
Server NIC.
Connecting the Imaging Server to a 7161
The 7161 uses a fiber port to connect to the Imaging Server. Media conversion
equipment may be required to connect to the Imaging Server or to a hub or
switch.
To cable a copper port on the Imaging Server directly to a 7161
1
Plug one end of an Ethernet cable into the RJ45 port on the Imaging Server.
2
Plug the other end of the cable into a media converter.
3
Plug the media converter into port 0 on the 7161.
This is the left-most top fiber port as viewed from the back.
4
Confirm that the link light is lit for port 0 on the 7161, and on the Imaging
Server NIC.
To connect the Imaging Server to a 7161 through a Base-T network device
1
Connect an Ethernet cable from the Imaging Server to the hub or switch.
2
Connect a second Ethernet cable from the hub or switch to a media
converter.
Note:
If you use a switch, configure it so that the two ports can pass network
traffic between them.
3
Connect the media converter into port 0 on the 7161.
This is the left-most top fiber port as viewed from the back.
4
Confirm that the link light is lit for port 0 on the 7160, and on the Imaging
Server NIC.
Re-imaging the appliance
For both an automatic and a standard Imaging Server, you must follow the same
procedure to re-image your appliance. Once you have completed the following
Содержание 10521148 - Network Security 7161
Страница 1: ...Symantec Network Security 7100 Series Implementation Guide...
Страница 8: ...8...
Страница 16: ...8 Contents...
Страница 24: ...16 Introduction Verifying the materials...
Страница 52: ...44 Deploying the 7100 Series Symantec LiveUpdate accessibility...
Страница 174: ...166 Maintaining and administering the 7100 Series Using the serial console...
Страница 190: ...182 Re imaging and unconfiguring About migration...
Страница 198: ...190 Specifications and safety Product certifications...
Страница 214: ...12 Index...