84
SVANTEK 977W User Manual
In case of
Program Update
the second
page consists of four positions, which
describe the status of program update, the
program to be updated (main or bootstrap),
version of the software and CRC.
▼
In case of
Date/Time Change
the second
page consists of five positions, which
describe the type of change (in this case
Time Correction
), previous time of the
instrument
display
(
Old
),
previous
correction
of
the
instrument
RTC
(
Old Correct.
), new time of the instrument
display (
New
), new correction of the
instrument RTC (
New Correct.
).
▼
If time correction was due to change from
Daylight
Saving
Time
(
DST
)
to
a
Standard Time
(
STD
) the second page
consists of five positions, which describe
the type of change (in this case
Standard
Time
), previous time of the
instrument display (
Old
), previous type of
time (
Old
), new time of the instrument
display (
New
), new type of time (
New
).
▼
In case of
Parameter Change
the second
page consists of three positions, which
describe the type of change, old and new
value of the parameter
▼
In case of
State of Seal
the second page
informs
what
change
was
done:
Remove Seal
or
Install Seal
.
▼
If seal and jumper are removed from the
bottom panel of the instrument the
instrument react on this with the text on
every screen „
Not legal
”, meaning that
measured results are not legal and
measurement results will not be saved in
the Welmec memory.