40
SVANTEK 977W User Manual
The
Logger
position switches on the
functionality, which enables the user to save
selected results from the three profiles,
spectra as well as meteo results, taken from
special Meteo module, with the defined
interval selected in the
Logger Step
position.
►
The
Summary Results
position allows the user to select or deselect the saving
of the full set of profile results that the instrument generates during total
measurement time and which are not belonged to the time history data. These
results are:
Spl
,
Leq, Sel
,
Lden
,
LEPd
,
Ltm3
,
Ltm5, LN%, LR15, LR60, Ovl,
Peak, Max, Min,
in case of sound measurements or
RMS
,
Ovl, Peak
,
P-P
,
MTVV
in case of vibration measurements as well as spectra in the analyzer
function. In addition to above mentioned results it is possible to add summary
meteo results, Statistics and Min and Max Spectra, listed the
Summary Results
window.
The
Logger Step
defines the period of the data logging in a file. It can be set
from 2 milliseconds to 1 second or the values from 1 second to 59 seconds or
the values from 1 minute to 59 minute and up to 1 hour.
The
Logger Name
position enables the user
to define the logger file name. The default
name is
L
. The name can be up to eight
characters long. After pressing the
◄ or ►
push-buttons, the special window with text
editing function is opened.
►
The edited name is accepted and saved after
pressing the
<ENTER>
push-button with
selected
Ok
field. The special warning is
displayed in case a file with the edited name
already exists in the memory. The instrument
waits then for a reaction of the user (any
push-button should be pressed except
<Shift>
or
<Alt>
).
<ENT>
The
Split
position enables the user to split the logger registration data into separate files. If
Split
parameter is
Off
the registration of time history data will be continuously performed in one logger file with the name defined
in the
Logger Name
position.
In other cases, the registration is performed
in separate files and the registration in the
new file will start: after integration period time
(
Integr. Period
), or every quarter of the RTC
(
Sync. to 15m
), or every half an hour of
the RTC
(
Sync. to 30m
), or every
hour of
the RTC (
Sync. to 1h
), or at specified by
the user times (
Spec. Time
)
. Every time
when the split time is achieved the logger file
is closed and new file with the increased by
►