SVAN 973 User Manual
47
Field description of the 3 Profiles mode
1.
Result for the first profile
2.
Result for the second profile
3.
Result for the third profile
4.
Implemented weighting filter:
A
,
C
,
Z
or
B
and
detector time constant:
I
(Impulse),
F
(Fast),
S
(Slow) when the detector is exponential or
L
when
the detector is linear
Changing measurement results
To change the result of the profile, you should select
the profile with the
▲
/
▼
key and then change the
result with the
◄
/
►
key.
The statistical levels can be changed with the
◄
/
►
key pressed with
<Shift>
.
▼
5.1.3 Logger view
In the
Logger
view, the time history results, selected in
the
Logger View
list, are displayed as a plot. You may
change viewed results by pressing the
<Enter>
key.
The cursor position can be changed with the
◄
/
►
key.
<ENT>
Logger view fields
1.
Logger Plot
2.
Result value for cursor position
3.
Result name (Profile number)
4.
Cursor time position
Note: If Logger (path: <Menu> / Measurement / Logging /Logger Set.) is switched off the
Logger presentation mode is disabled! Therefore, to have this presentation mode active,
switch the Logger on!
Note: When Logger is switched on, but results were not selected for logging the Logger
presentation mode is disabled!
5.1.4 Statistics view
“Statistics” is the cumulative probability density function of exceeding the noise level during the
measurement period. The X axis defines the probability of exceeding the noise level, statistical level
Ln
,
and the axis Y defines the calculated noise level in dB.
1
2
3
2
3
4
1
4
Содержание SV 973
Страница 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 192: ...SVAN 973 User Manual Appendixes 192 LF filter according to EPA 93 F105 02 104 Low Frequency Noise Control Regulations...