The
USB-C Device
2.0 interface is the serial interface working with 12 MHz clock in the full speed mode
and with 480 MHz in the high-speed mode, which is a default mode of the instrument. Thanks to its
speed, it is widely used in all PCs. The standard 4-pin socket is described in detail in Appendix C.
Note: Switch the power off before connecting the instrument to any other device (e.g. a printer
or a Personal Computer) or fitting the microphone capsule.
2.2 I
NSTRUMENT POWER
SV 973 can be powered by one of the following sources:
•
Four AAA standard size batteries fitted internally. In the case of alkaline type, a new fully charged
set can operate more than 20 h (6.0 V / 0.8 Ah). Measurements with the display off extend the
working time to more than 30 h.
•
USB-C
interface
– 100 mA HUB.
When the instrument is powered from internal batteries,
the
“battery”
icon is presented on the top line
of the display.
The battery condition can be checked through the
Battery
screen. It is also presented continuously on
the top line of the display by means of the number of bars in the
“battery”
icon.
When voltage of the batteries is too low for reliable measurements, the icon is red and during attempt to
switch the instrument on, the
Low Battery!
message occurs on the display for 2 seconds and the
instrument switches off by itself.
Powering the instrument from the USB-C interface is performed by
connecting its
USB
socket to the PC or other USB power source via the
SC 158 cable.
When the USB is connected, the instrument automatically switches
powering from the internal batteries to the USB powering. After
disconnection the USB, the instrument will automatically switch
powering to the internal batteries.
Note: When the instrument is powering via USB, the internal batteries are slightly discharging.
You should remember about this effect and remove the battery if discharging is undesirable.
Note: Use only high-quality USB-C cables, such as SC 158. Many poor-quality cables do not
ensure low resistance of the cable, thus disabling proper operating of the instrument.
When there is a connection to the USB-C interface (
USB Device
socket is connected by the SC 158
cable to a PC), the
“USB”
icon is presented on the top of the display and the
Battery
screen displays
the source voltage.
Note: In case the
“battery” icon is red, it is strongly recommended to use USB-C interface as
soon as possible to ensure reliable operation. If no suitable external power source is provided
the instrument will be switched off automatically
after a short time!
Prolonging
the internal source of the instrument’s power can be achieved by means of the LCD screen
Dim Mode
. You can configure the power saver function (
Dim Mode
) in the
Screen Set.
screen (
path:
<Menu> / Display / Screen Set.)
.
2.3 C
ONTROL KEYS ON THE FRONT PANEL
Control of the instrument has been developed in a fully interactive manner. The user can operate the
instrument by selecting the appropriate position from the screen
Menu
list. Thanks to that, the number
of the control keys of the instrument has been reduced to eight for ease of use and convenience.
Содержание SV 973
Страница 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 192: ...SVAN 973 User Manual Appendixes 192 LF filter according to EPA 93 F105 02 104 Low Frequency Noise Control Regulations...