![Svantek SV 973 Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/svantek/sv-973/sv-973_user-manual_1409271133.webp)
SVAN 973 User Manual
– Appendixes
133
…
1
x - depends of the filter type for Peak result calculation in selected profile: A, C, Z, B (cf.
Tab. B.1.12)
2
x - depends of the filter type in selected profile: A, C, Z, B, LF (cf. Tab. B.1.12)
y - depends of the detector type in selected profile: I (imp.), F (fast), S (slow) (cf. Tab. B.1.12)
3
y - only for exponential detector's type (cf. Tab. B.1.6)
Table B.1.13. Display settings of the main results
Word
number
Name
Comment
0
0xnn48
[48, nn=header’s length]
1
TIME
0
– TIME result not displayed, 1 - TIME result displayed
2
Lpeak
0
– Lxpeak
1
result not displayed, 1
– Lxpeak
1
result displayed
3
Lmax
0
– Lxymax
2
result not displayed, 1
– Lxymax
2
result displayed
4
Lmin
0
– Lxymin
2
result not displayed, 1
– Lxymin
2
result displayed
5
L
0
– Lxy
2
result not displayed, 1
– Lxy
2
result displayed
6
DOSE
0
– DOSE result not displayed, 1 - DOSE result displayed
7
D_8h
0
– D_8h result not displayed, 1 - D_8h result displayed
8
LAV
0
– LAV result not displayed, 1 - LAV result displayed
9
Leq
0
– Lxyeq
23
result not displayed, 1
– Lxyeq
23
result displayed
10
LE
0
– LxyE
23
result not displayed, 1 - LxyE
23
result displayed
11
SEL8
0
– SEL8 result not displayed, 1 - SEL8 result displayed
12
E
0
– E result not displayed, 1 – E result displayed
13
E_8h
0
– E_8h result not displayed, E_8h 1 - result displayed
14
Lden
0
– Lden result not displayed, 1 - Lden result displayed
15
LEPd
0
– LEPd result not displayed, 1 - LEPd result displayed
16
PSEL
0
– PSEL result not displayed, 1 - PSEL result displayed
17
Ltm3
0
– Ltm3 result not displayed, 1 - Ltm3 result displayed
18
Ltm5
0
– Ltm5 result not displayed, 1 - Ltm5 result displayed
19
Ln
0
– Ln result not displayed, 1 - Ln result displayed
20
PTC
0
– PTC result not displayed, 1 - PTC result displayed
21
PTP
0
– PTP result not displayed, 1 - PTP result displayed
22
ULT
0
– ULT result not displayed, 1 - ULT result displayed
23
TWA
0
– TWA result not displayed, 1 - TWA result displayed
24
PrDOSE
0
– PrDOSE result not displayed, 1 - PrDOSE result displayed
25
PrTWA
0
– PrTWA result not displayed, 1 - PrTWA result displayed
26
LR15
0
– LR15 result not displayed, 1 - LR15 result displayed
27
LR60
0
– LR60 result not displayed, 1 - LR60 result displayed
28
LCA
0
– Lc-a result not displayed, 1 – Lc-a result displayed
29
OVL
0
– OVL result not displayed, 1 - OVL result displayed
30
LeqLF
0
– LeqLF result not displayed, 1 - LeqLF result displayed
…
…
…
1
x - depends of the filter type for Peak result calculation in selected profile: A, C, Z, B (cf.
Tab. B.1.12)
2
x - depends of the filter type in selected profile: A, C, Z, B, LF (cf. Tab. B.1.12)
y - depends of the detector type in selected profile: I (imp.), F (fast), S (slow) (cf. Tab. B.1.12)
3
y - only for exponential detector's type (cf. Tab. B.1.6)
Содержание SV 973
Страница 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 192: ...SVAN 973 User Manual Appendixes 192 LF filter according to EPA 93 F105 02 104 Low Frequency Noise Control Regulations...