2.3 I
NSTRUMENT POWER
SV 971A can be powered by one of the following sources:
•
Four AAA standard size batteries fitted internally. In the case of alkaline type, a new fully charged
set can operate more than 12 h (6.0 V / 1.6 Ah). Instead of the ordinary alkaline cells, four AAA
rechargeable batteries can be used (a separate external charger is required for charging them). In
this case, using the best NiMH type, the operation time can be increased up to 16 h (4.8 V / 2.6 Ah)
•
USB-C
interface
– 100 mA HUB.
When the instrument is powered from internal batteries,
the
“battery”
icon is presented on the top line
of the display.
The battery condition can be checked through the
Battery
screen. It is also presented continuously on
the top line of the display by means of the number of bars in the
“battery”
icon.
When voltage of the batteries is too low for reliable measurements, the icon is red and during attempt to
switch the instrument on, the
Low Battery!
message occurs on the display for 2 seconds and the
instrument switches off by itself.
Powering the instrument from the USB interface is performed by
connecting its
USB
socket to the PC or other USB power source via the
SC 158 cable.
When the USB is connected, the instrument automatically switches
powering from the internal batteries to the USB powering. After
disconnection the USB, the instrument will automatically switch power
to the internal batteries.
Note: When the instrument is powered via USB, the internal batteries slightly discharge. You
should remember about this effect and remove the battery if discharging is undesirable.
Note: Use only high-quality USB-C cables, such as SC 158. Many poor-quality cables do not
ensure low resistance of the cable, thus disabling proper operating of the instrument.
When there is a connection to the USB interface (
USB Device
socket is connected by the SC 158 cable
to a PC), the
“USB”
icon is presented on the top of the display and the
Battery
screen displays the
source voltage.
Note: In case the
“battery” icon is red, it is strongly recommended to use USB interface as
soon as possible to ensure reliable operation. If no suitable external power source is provided
the instrument will be switched off automatically
after a short time!
Prolonging the internal source of the instru
ment’s power can be achieved by means of the LCD screen
Dim Mode
. You can configure the power saver function (
Dim Mode
) in the
Screen Set.
screen (
path:
<Menu> / Display / Screen Set.)
.
Содержание SV 971A
Страница 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Страница 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Страница 245: ...SV 971A User Manual Appendixes 245 8 0 kHz 1 1 octave filter 4 0 kHz 1 1 octave filter 2 0 kHz 1 1 octave filter...
Страница 246: ...SV 971A User Manual Appendixes 246 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 247: ...SV 971A User Manual Appendixes 247 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter...
Страница 254: ...SV 971A User Manual Appendixes 254 Z filter Class 1 according to IEC 61672 1 2013 Z filter characteristics...
Страница 273: ...SV 971A User Manual Appendixes 273 250 Hz 315 Hz 0 deg 90 deg 0 deg 90 deg 400 Hz 500 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 274: ...SV 971A User Manual Appendixes 274 630 Hz 800 Hz 0 deg 90 deg 0 deg 90 deg 1000 Hz 1250 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 275: ...SV 971A User Manual Appendixes 275 1600 Hz 2000 Hz 0 deg 90 deg 0 deg 90 deg 2240 Hz 2500 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 276: ...SV 971A User Manual Appendixes 276 2800 Hz 3150 Hz 0 deg 90 deg 0 deg 90 deg 3550 Hz 4000 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 277: ...SV 971A User Manual Appendixes 277 4500 Hz 5000 Hz 0 deg 90 deg 0 deg 90 deg 5600 Hz 6300 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 278: ...SV 971A User Manual Appendixes 278 7100 Hz 8000 Hz 0 deg 90 deg 0 deg 90 deg 8500 Hz 9000 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...