If the parameter has a numerical value, you can speed up a selection by pressing the
◄
/
►
key and
keeping it pressed by more than 2 seconds. In this case, the parameter value starts changing
automatically until you release the pressed button.
You may change the numerical parameter value with a larger step (usually 10) with the
◄
/
►
key
pressed with
<Shift>
.
Matrix of parameters
When a list of parameters consists of more than one column you may change:
•
column with the
◄
/
►
key
•
line with the
▲
/
▼
key
•
value in a selected position with the
◄
/
►
key pressed with
<Shift>
•
all values in a line with the
▲
/
▼
key pressed with
<Shift>
•
all values in a column, if the cursor is on one of Profile positions, with the
◄
/
►
key pressed with
<Shift>
•
all values in a matrix, if the cursor is on one of Profile positions, with the
▲
/
▼
key pressed with
<Shift>
.
List of options
In the list of options, you can select only one option. The selection of an option
is performed in the following way. Select the desired option with the
▲
/
▼
key
and press
<Enter>
. This option becomes active and the list is closed. After re-
entering this list again, the last selected option will be marked.
Complex parameters
For complex parameters, consisted of more than one value field like
RTC
, you
should select the field with the
◄
/
►
/
▲
/
▼
key and then select the value with
the
◄
/
►
key pressed with
<Shift>
. The selection should be confirmed by
<Enter>
.
In all cases the
<Enter>
key is used for confirmation of changes and for closing the list. The list is closed,
ignoring any made changes with the
<ESC>
key.
Text editor screen
In the text editor screens, you may edit text lines (file
names, directory name etc.) The text editor screen is
opened with the ◄ / ► key when the position with the
text parameter is selected. These screens provide help
information on how to edit text.
►
•
Use the
◄
/
►
key to select a position of the character in the edited text.
•
Use the
▲
/
▼
key to change the existing character with another ASCII character. The subsequent
digits, underline, upper case letters and space appear in the inversely displayed position after each
press of said key.
•
Use the
◄
/
►
key pressed with
<Shift>
to insert or delete a position in the edited text.
Information screen
Some screens inform about the state of the instrument, available memory,
standards fulfilled by the instrument, etc. To scroll through the screen, use the
▲
/
▼
keys. To close such a screen, press
<ESC>
or
<Enter>
.
Содержание SV 971A
Страница 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Страница 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Страница 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Страница 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Страница 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Страница 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Страница 245: ...SV 971A User Manual Appendixes 245 8 0 kHz 1 1 octave filter 4 0 kHz 1 1 octave filter 2 0 kHz 1 1 octave filter...
Страница 246: ...SV 971A User Manual Appendixes 246 1 0 kHz 1 1 octave filter 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...
Страница 247: ...SV 971A User Manual Appendixes 247 125 Hz 1 1 octave filter 63 0 Hz 1 1 octave filter 31 5 Hz 1 1 octave filter...
Страница 254: ...SV 971A User Manual Appendixes 254 Z filter Class 1 according to IEC 61672 1 2013 Z filter characteristics...
Страница 273: ...SV 971A User Manual Appendixes 273 250 Hz 315 Hz 0 deg 90 deg 0 deg 90 deg 400 Hz 500 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 274: ...SV 971A User Manual Appendixes 274 630 Hz 800 Hz 0 deg 90 deg 0 deg 90 deg 1000 Hz 1250 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 275: ...SV 971A User Manual Appendixes 275 1600 Hz 2000 Hz 0 deg 90 deg 0 deg 90 deg 2240 Hz 2500 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 276: ...SV 971A User Manual Appendixes 276 2800 Hz 3150 Hz 0 deg 90 deg 0 deg 90 deg 3550 Hz 4000 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 277: ...SV 971A User Manual Appendixes 277 4500 Hz 5000 Hz 0 deg 90 deg 0 deg 90 deg 5600 Hz 6300 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 278: ...SV 971A User Manual Appendixes 278 7100 Hz 8000 Hz 0 deg 90 deg 0 deg 90 deg 8500 Hz 9000 Hz 0 deg 90 deg 0 deg 90 deg...
Страница 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...