VL1500K5 (’05-MODEL) 69
Step 2
1) Turn the ignition switch OFF.
2) Measure the IAT sensor resistance.
"
IAT sensor resistance: Approx. 2.45 k
Ω
at 20 °C (68 °F)
(Terminal – Terminal)
#
09900-25008: Multi-circuit tester set
)
Tester knob indication: Resistance (
Ω
)
Is the resistance OK?
"
IAT sensor specification
NOTE:
IAT sensor resistance measurement method is the same way as
that of the EOT sensor. Refer to page 62 for details.
1
YES
• Dg or B/Br wire open or shorted to ground, or
poor
2
or
D
connection.
• If wire and connection are OK, intermittent trou-
ble or faulty ECM.
• Recheck each terminal and wire harness for
open circuit and poor connection.
• Replace the ECM with a known good one, and
inspect it again.
NO
Replace the IAT sensor with a new one.
Intake Air Temp
Resistance
20 °C (68 °F)
Approx. 2.45 k
Ω
40 °C (104 °F)
Approx. 1.148 k
Ω
60 °C (140 °F)
Approx. 0.587 k
Ω
80 °C (176 °F)
Approx. 0.322 k
Ω
ECM coupler (Harness side)
1
SA
MP
LE
Содержание 2005 VL1500K5
Страница 1: ...VL1500 USE THIS MANUAL WITH VL1500 SERVICE MANUAL 99500 39166 01E...
Страница 156: ...VL1500K5 05 MODEL 155 FRAME HEAD COVER INSTALLATION 1 Cushion seat 3 3 mm 0 12 in 2 Apply an adhesive agent SAMPLE...
Страница 180: ...Prepared by May 2004 Part No 99501 39550 01E Printed in Japan 176 SAMPLE...
Страница 181: ...Printed in Japan K5...