VL1500K5 (’05-MODEL) 23
Continuity check
• Measure resistance across coupler
B
(between
A
and
C
in
the figure).
If no continuity is indicated (infinity or over limit), the circuit is
open between terminals
A
and
C
.
• Disconnect the coupler
B
and measure resistance between
couplers
A
and
B
.
If no continuity is indicated, the circuit is open between cou-
plers
A
and
B
. If continuity is indicated, there is an open cir-
cuit between couplers
B
’ and
C
or an abnormality in coupler
B
’ or coupler
C
.
VOLTAGE CHECK
If voltage is supplied to the circuit being checked, voltage check
can be used as circuit check.
• With all connectors/couplers connected and voltage applied
to the circuit being checked, measure voltage between each
terminal and body ground.
If measurements were taken as shown in the figure at the right
and results are as listed below, it means that the circuit is open
between terminals
A
and
B
.
Voltage Between:
C
and body ground: Approx. 5 V
B
and body ground: Approx. 5 V
A
and body ground:
0 V
Also, if measured values are as listed below, a resistance
(abnormality) exists which causes the voltage drop in the circuit
between terminals
A
and
B
.
Voltage Between:
C
and body ground: Approx. 5 V
B
and body ground: Approx. 5 V
2 V voltage drop
A
and body ground:
3 V
ECM
ECM
0 V
5 V
5 V
5 V
SA
MP
LE
Содержание 2005 VL1500K5
Страница 1: ...VL1500 USE THIS MANUAL WITH VL1500 SERVICE MANUAL 99500 39166 01E...
Страница 156: ...VL1500K5 05 MODEL 155 FRAME HEAD COVER INSTALLATION 1 Cushion seat 3 3 mm 0 12 in 2 Apply an adhesive agent SAMPLE...
Страница 180: ...Prepared by May 2004 Part No 99501 39550 01E Printed in Japan 176 SAMPLE...
Страница 181: ...Printed in Japan K5...