![Sutron MONITOR Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/sutron/monitor/monitor_operation-and-maintenance-manual_1407880058.webp)
Method 1: Using ‘UPGRADE’ command using HyperTerminal:
Open and run HyperTerminal on a PC. Set the properties to:
Baud Rate: 115200
Bits:
8
Parity:
None
Stop Bits: 1
•
Start with the Sutron unit powered up and running.
•
Connect DB-9 serial cable and establish communications by typing ‘enter’.
(connect port)
•
Once the prompt is found, type ‘UPGRADE” or ‘UPG’.
•
Now the system is waiting for HyperTerminal to send the file.
•
An upper case “C” will repeat every 2 seconds or so over the serial port. Select
‘Send File” and choose ‘Y-Modem’ and then select the upgrade file name
previously stored on the computer.
•
Once the download is completed, the system will reboot.
•
Type the command ‘Ver’ to confirm that the upgrade was successful
Method 2: Using HyperTerminal and ‘Escape’ key:
Open and run HyperTerminal on a PC. Set the properties to:
Baud Rate: 115200
Bits:
8
Parity:
None
Stop Bits: 1
•
Start with the Sutron unit powered DOWN.
•
Open the serial port with HyperTerminal.
•
Power up the Sutron unit simultaneously while holding the ‘Escape’ key on the
keyboard of the computer running HyperTerminal. Release the escape key once
the unit has powered up.
•
An upper case “C” will repeat every 2 seconds or so over the serial port. At this
time, use ‘Send File’ and choose ‘Y-Modem’ and then select the upgrade file
name previously stored on the computer.
•
Once the download is completed, the system will reboot.
•
Type the command ‘Ver’ to confirm that the upgrade was successful.
Connecting a Modem
It is possible to connect a modem to MONITOR, allowing for remote access to the
station. Use the RS232 port to connect the modem. Most modems will need a null
modem adapter between the modem and MONITOR.
The modem will need to be configured before it can be used. Please make sure to test out
the modem- MONITOR connection before deploying them in the field. The following
modem settings must be configured:
58