![Sutron MONITOR Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/sutron/monitor/monitor_operation-and-maintenance-manual_1407880033.webp)
Connect the sensor as follows:
Excitation
(VREF)
Analog
Gnd
_
“DIFF C” input
4 5 6 7
+
Terminal
Block
Description
Pressure Transducer
Pin Description
COLOR
4 AGND Negative
Supply WHITE
5 VREF Positive
Supply RED
6
DIFF ‘C’ (+)
Positive Output
YELLOW
7
DIFF ‘C’ (- )
Negative Output
BLUE
NOTE: Connect the shield wire on the pressure transducer to the earth ground on the
side of the Monitor. The wire color column refers to a Druck PDCR 1830 series Sensor.
The setup to have the MONITOR measure STAGE from the sensor in units of feet is as
follows:
Stage setup
Value
Active
On
Label
Stage
Meas Type
Analog
Analog Type
Diff C
Input Range
-39 to +39mV
Warmup
1 sec
Averaging Time
00:00:00
Slope 922.92
The slope is calculated as follows:
(10 PSI / 25 mV) * (1000 mV / 1 V) * (2.3073 feet / PSI) = 922.92 feet / V
33