System Fans
Four 8-cm fans and an air shroud (which channels the air flow to the
processors) provide all the cooling needed for the SuperServer 6024H-8R/
6024H-i. It is very important that the chassis top cover is properly installed
and making a good seal in order for the cooling air to circulate properly
through the chassis and cool the components. See Figure 6-2.
System Fan Failure
The fans run at 6300 rpm. If a fan fails, the ambient air temperature in the
chassis will rise and activate the overheat LED on the control panel. Re-
place any non-working fan immediately. The hot plug fan will start to func-
t i o n u p o n c o n n e c t i o n t o i t s f a n h e a d e r o n t h e X 6 D H 8 - G / X 6 D H E - G
serverboard.
Replacing System Fans
1.
Removing a fan
Remove the chassis cover. Press the tabs on the top of the fan housing
and remove the fan and its housing. System power does not need to be shut
down since the fans are all hot-pluggable.
2.
Installing a new fan
Replace the failed fan with an identical 8-cm, 12 volt fan (available from
Supermicro, p/n FAN-0070). Position the new fan at its proper place in
the chassis by fitting the fan with its housing onto the fan mounts in the
chassis. A "click" can be heard if the fan (in its housing) is properly
installed. If the system power is on, the hot-plug feature will cause the fan to
start immediately upon being connected to its header on the serverboard.
6-2
Control Panel
The control panel (located on the front of the chassis) must be connected
to the JF1 connector on the serverboard to provide you with system status
indications. A ribbon cable has bundled these wires together to simplify the
connection. Connect the cable from JF1 on the serverboard to JP4 on the
Control Panel PCB (printed circuit board). Make sure the red wire plugs into
pin 1 on both JF1 and JP4. Pull all excess cabling out of the airflow path.
The LEDs inform you of system status. See Chapter 3 for details on the
LEDs and the control panel buttons. Details on JF1 can be found in Chapter
5.
Содержание SuperServer 6024H-8R
Страница 1: ...SUPERSERVER 6024H 8R SUPERSERVER 6024H i USER SMANUAL 1 0 SUPER NIC 1 NIC 2...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes x SUPERSERVER 6024H 8R 6024H i Manual...
Страница 25: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the System P4D P6 UP ER S...
Страница 30: ...SUPERSERVER 6024H 8R 6024H i User s Manual 3 4 Notes...
Страница 58: ...5 24 SUPERSERVER 6024H 8R 6024H i Manual Notes...
Страница 94: ...7 24 SUPERSERVER 6024H 8R 6024H i Manual Notes...
Страница 100: ...A 6 SUPERSERVER 6024H 8R 6024H i Manual Notes...
Страница 124: ...C 4 SUPERSERVER 6024H 8R 6024H i Manual Notes...