Chapter 6: Advanced Chassis Setup
6-3
Adding a System Fan
Turn off the power to the system and unplug the power cord.
1.
Remove the chassis cover then remove the dummy fan from the fan tray.
2.
Place the new fan into the vacant space in the housing while making sure the
3.
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
Connect the fan wires to the fan header on the serverboard.
4.
Power up the system and check that the fan is working properly before re-
5.
placing the chassis cover.
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails,
the remaining fans will ramp up to full speed. Replace any failed fan at your earli-
est convenience with the same type and model (the system can continue to run
with a failed fan).
The SC113M chassis includes four pre-installed fans. Two additional open slots are
available so that. up to two more fans may be added.
Replacing a System Fan (Figure 6-2)
Open the chassis while the system is running to determine which fan has
1.
failed. Never run the server for an extended period of time with the chassis
open.
Turn off the power to the system and unplug the power cord.
2.
Remove the failed fan's wiring from the fan header on the serverboard.
3.
Lift the failed fan from the chassis and pull it completely out.
4.
Place the new fan into the vacant space in the housing while making sure the
5.
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
Reconnect the fan wires to the same chassis fan header as the previous fan.
6.
Power up the system and check that the fan is working properly before re-
7.
placing the chassis cover.
Содержание SuperServer 1025C-M3
Страница 1: ...SUPER USER S MANUAL Revision 1 0 SUPERSERVER 1025C M3...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 1025C M3 User s Manual x Notes...
Страница 23: ...Chapter 2 Server Installation 2 7 Figure 2 4 Installing the Outer Rails to the Rack 2 3 3...
Страница 28: ...2 12 SUPERSERVER 1025C M3 Manual Notes...
Страница 32: ...3 4 SUPERSERVER 1025C M3 Manual Notes...
Страница 69: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 5 Installing a DVD ROM Drive...
Страница 71: ...Chapter 6 Advanced Chassis Setup 6 9 Figure 6 6 Removing Replacing the Power Supply...
Страница 72: ...6 10 SUPERSERVER 1025C M3 Manual Notes...
Страница 100: ...A 6 SUPERSERVER 1025C M3 User s Manual Notes...
Страница 106: ...B 6 SUPERSERVER 1025C M3 User s Manual Notes...
Страница 110: ...C 4 SUPERSERVER 1025C M3 User s Manual Notes...