Chapter 6: Advanced Chassis Setup
6-9
6-5
Power Supply
The SuperServer 6014A-8 has a single 500 watt power supply, which is
auto-switching capable. This enables it to automatically sense and operate
with a 100v - 240v input. An amber light will be illuminated on the power
supply when the power is off. An illuminated green light indicates that the
power supply is operating.
Power Supply Failure
If the power supply unit fails, the system will shut down and you will need
to replace the unit. Replacement units can be ordered directly from
Supermicro (see contact information in the Preface). As there is only one
power supply unit in the 6014A-8, power must be completely removed from
the server before removing and replacing the power supply unit for what-
ever reason.
Removing/Replacing the Power Supply
1.
Removing the power supply
First turn the power switch on the control panel off, then unplug the
power cord from the system. Remove the chassis cover by pressing the
two release buttons on the top of the chassis (near the front) and push
the chassis top rearward about one inch. To remove the failed power
unit, push the beige colored release tab to the right and then carefully lift
the unit up about 1/2 inch only. If you lift too high, you may damage the
power distribution board that the other end of the unit is connected to.
Then, pull the power unit straight back to unplug it from the power
distribution board. See Figure 6-6.
2.
Installing a new power supply
Replace the failed unit with another unit of the same input voltage, output
voltage and wattage. It is highly recommended to replace it with exactly
the same model power supply (PWS-0048). Carefully insert the new unit
into position to plug it into the power distribution board, making sure you
are not holding it at too great an angle, which may damage the power
distribution board. Push it completely into the power distribution board
and seat it in the chassis. When correctly installed it should be laying
flat - make sure the end of the power supply is not sitting on the stop in
the chassis. Reconnect the power cord, replace the chassis top cover
and reposition the unit back into the rack. Finish by depressing the
power button on the chassis front control panel.
Содержание SUPERSERVER 6014A-8
Страница 1: ...SUPERSERVER 6014A 8 USER SMANUAL 1 0 SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6014A 8 Manual x Notes...
Страница 18: ...SUPERSERVER 6014A 8 Manual 1 8 Notes...
Страница 32: ...3 4 SUPERSERVER 6014A 8 Manual Notes...
Страница 60: ...5 24 SUPERSERVER 6014A 8 Manual Notes...
Страница 70: ...6 10 SUPERSERVER 6014A 8 Manual Figure 6 6 Removing Replacing the Power Supply with optional front bezel shown...
Страница 94: ...7 24 SUPERSERVER 6014A 8 Manual Notes...
Страница 100: ...A 6 SUPERSERVER 6014A 8 Manual Notes...
Страница 106: ...B 6 SUPERSERVER 6014A 8 Manual Notes...
Страница 130: ...SUPERSERVER 6014A 8 Manual D 4 Notes...