System Fans
Two 10-cm blower fans provide all the cooling needed for the SuperServer
6014A-8. It is very important that the chassis top cover is properly installed
and making a good seal in order for the cooling air to circulate properly
through the chassis and cool the components. See Figure 6-2.
Fan speed is controlled by a setting in BIOS (see page 7-18). For the
6014A-8, the recommended setting is "3-wire (Server)".
System Fan Failure
If a fan fails, the ambient air temperature in the chassis will rise and acti-
vate the overheat LED on the control panel. Replace any failed fan immedi-
ately with the same type and model. You must power down the system
before replacing a cooling fan (removing the power cord is also recom-
mended as a safety precaution).
Replacing System Fans
1.
Removing a fan
After turning off the power to the system, first remove the chassis cover
and unplug the fan cable from the motherboard. Unscrew the failed
blower fan from the chassis and pull it completely out from the
serverboard.
2.
Installing a new fan
Replace the failed fan with an identical 10-cm, 12 volt fan (available from
Supermicro: p/n FAN-0059). Install the new fan in its proper place in the
chassis by positioning it on the two mounting posts. Secure the fan to
the chassis with the screws you removed previously, then attach the fan
wires to the same chassis fan header you removed it from. Make sure
the air seal under the fan is properly installed and creating a good seal.
Power up the system and check that the fan is working properly and that
the LED on the control panel has turned off. Finish by replacing the
chassis cover.
Содержание SUPERSERVER 6014A-8
Страница 1: ...SUPERSERVER 6014A 8 USER SMANUAL 1 0 SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6014A 8 Manual x Notes...
Страница 18: ...SUPERSERVER 6014A 8 Manual 1 8 Notes...
Страница 32: ...3 4 SUPERSERVER 6014A 8 Manual Notes...
Страница 60: ...5 24 SUPERSERVER 6014A 8 Manual Notes...
Страница 70: ...6 10 SUPERSERVER 6014A 8 Manual Figure 6 6 Removing Replacing the Power Supply with optional front bezel shown...
Страница 94: ...7 24 SUPERSERVER 6014A 8 Manual Notes...
Страница 100: ...A 6 SUPERSERVER 6014A 8 Manual Notes...
Страница 106: ...B 6 SUPERSERVER 6014A 8 Manual Notes...
Страница 130: ...SUPERSERVER 6014A 8 Manual D 4 Notes...