Chapter 4
Servicing Motherboard Components
4-45
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Remove the mezzanine tray.
See
Section 4.2.1, “Removing the Mezzanine Tray” on page 4-13
.
3. Remove the heat sink on top of the failed CPU.
Each screw
must
be turned no more than one 1/2 turn before moving over to the
other screw and doing the same. Continue to turn each screw one 1/2 turn,
moving back and forth between the two screws until both screws are removed.
4. Remove the failed CPU.
5. Clean off the old thermal interface material from the heat sink and CPU, using
the supplied alcohol wipe. (
FIGURE 4-19
)
6. Set the heat sink aside.
7. Place the new CPU in the socket.
Make sure the orientation is correct.
Be careful not to contact the gold fingers within the socket.
FIGURE 4-19
Installing a CPU
8. Engage the lever by rotating downward and pressing it into the catch.
9. Using the supplied grease syringe, empty the syringe on to the CPU in a star
shaped pattern. (
FIGURE 4-20
)
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...