1-2
Sun Fire X4440 Server Service Manual • September 2010
The product features are listed in
TABLE 1-1
.
TABLE 1-1
Sun Fire X4440 Server System Features
Feature
Description (Sun Fire X4440)
Processor
AMD64 Opteron Socket F [1207] (1 MByte L2 cache per CPU chip) – dual
core capable. Supports dual, and quad core.
Memory
8 DDR-2 DIMM slots per socket. Up to 800 MHz memory speeds
depending upon processor type and memory configuration. PC2-4200R
533 MHz Registered DIMMs with ECC PC2-5300R 667 MHz
Registered DIMMs with ECC
PC2-6400R 800 MHz Registered DIMMs with ECC
1GB, 2GB, 4GB, or 8GB per DIMM
See
Section 4.1.2, “DDR2 DIMM Guidelines” on page 4-5
.
Ethernet ports
4 ports, 10/100/1000 Mbps, auto-negotiating through two separate
controllers
Internal drives
SAS (up to 8) or SATA (up to 8) disk drives, and SSDs (up to 4).
Up to 8 SFF SAS 73-GB or 146-GB 2.5-inch form factor drives. Support for
hardware-embedded RAID 0 (striping) and RAID 1 (mirroring)
Optional RAID Levels 0, 1, IE, 5, 5EE, 6, 10, 50, 60 with SAS drives
Removable
media
1 slimline DVD drive, supporting CD-R/W, CD+R/W, DVD-R/W,
DVD+R/W
USB ports
5 USB 2.0 ports: 2 in front, 2 in rear, plus 1 internal USB port
Service ports
1 RJ-45 serial management port (SER MGT)
(default connection to access service processor)
1 10-MB network management port (NET MGT)
(to access service processor)
HD15 VGA video port to view redirected service processor video.
Cooling
6 hot-service system fan modules (2 fans per module)
An air duct facilitates processor/memory airflow
PCI interfaces
6 standard low-profile PCIe slots on three riser boards
(2 - x8 and 4 - x4 electrical / 3 - x16 and 3 - x8 mechanical)
See
Section 4.5.1, “Sun Fire X4440 PCIe Card Guidelines” on page 4-25
.
Power
AC power: 100-240VAC, 12-5A, 50-60Hz
1 or 2 hot-service 1050W power supply units (PSUs) to provide N+N
redundancy, with energy efficient design
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...