4-54
Sun Fire X4440 Server Service Manual • September 2010
3. Once the flash device is booted, run the following command:
socflash -p 1 -f
<sp-binary-file>
For Example:
socflash -p 1 -f g12n.bin
If you want to back up the current flash content, run following command:
socflash -p 1 -f
<sp-binary-file>
-b
<backup-binary-file>
For example:
socflash -p 1 -f g12n.bin -b ilombak.bin
Note –
If you choose to back up the SP binary (
-b
<backup-filename>
), you must
ensure there is sufficient free space on the USB flash device to hold the backup file.
Note –
Use the command
socflash -h
to get a complete option listing.
4. After a successful flash, perform an AC power cycle or reset the SP using the
following command:
socflash -r
Note –
Using
-r
(resetting the SP hardware) can cause the VGA display to become
disrupted.
Note –
The BIOS is not upgraded by this emergency recovery procedure. Perform a
2nd ILOM-based flash upgrade, to update the BIOS version.
Note –
This emergency flash recovery procedure returns the SP to default
configuration.
5. Press F2 to enter system BIOS and verify that the flash device is in the boot
order.
6. After a successful flash, remove the flash drive from the USB port.
7. AC power cycle the server.
Wait at least 2 minutes to let SP come up first.
8. Power on the server and enter BIOS.
9. Confirm following items are correct in BIOS:
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...