4-8
Sun Fire X4440 Server Service Manual • September 2010
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
3. If you are replacing a faulty DDR2 DIMM, press the Fault Remind button on
the motherboard and mezzanine tray to locate the DDR2 DIMM that you want
to replace.
The faulty DDR2 DIMM LED flashes when the Fault Remind button is pressed
and held. All faulty DIMMs are indicated with an amber LED, so that you can
install the replacement DDR2 DIMM in the same location.
4. Do one of the following.
■
If the faulty DIMM is located on the mezzanine board, then lift up the air duct.
(
FIGURE 4-4
[1]).
■
If the faulty DIMM is located on the motherboard, then remove the mezzanine
tray. See
Section 4.2, “Servicing the Mezzanine Tray” on page 4-12
.
Tip –
Make a note of the faulty DDR2 DIMM location.
5. Push down on the ejector tabs on each side of the DDR2 DIMM until the
DIMM is released (
FIGURE 4-4
).
6. Grasp the top corners of the faulty DDR2 DIMM and remove it from the server.
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...