![Sun Oracle Fire X4440 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/sun-oracle/fire-x4440/fire-x4440_service-manual_1393130089.webp)
Chapter 4
Servicing Motherboard Components
4-25
Note –
CRU
: This customer-replaceable unit can be replaced by anyone.
Caution –
This procedure requires that you handle components that are sensitive to
static discharge. This sensitivity can cause the component to fail. To avoid damage,
ensure that you follow antistatic practices as described in
Section 2.8, “Performing
Electrostatic Discharge and Antistatic Prevention Measures” on page 2-10
.
Caution –
Ensure that all power is removed from the server before removing or
installing expansion cards. You must disconnect the power cables before performing
this procedure.
4.5.1
Sun Fire X4440 PCIe Card Guidelines
The PCI expansion system is configured using two types of riser cards.
Riser type 1 is used in the Riser 0 and Riser 1 positions and Riser type 2 is used in the
slot 2 position as shown in
TABLE 4-1
. The electrical width is the number of active
PCIe lanes and the mechanical width desicribes the riser PCIe connector size. PCIe
cards with x4, x8 or x16 mechanical finger pins will fit in any riser slot but will
operate at the electrical lane width of the slot.
Note –
The SGXPCIESAS-R-INT-Z HBA should be installed in slot 0 to avoid system
overheating. Make sure that the firmware is at SW 3.1 or later when installing the
HBA in Slot 0.
TABLE 4-1
Sun Fire X4440 Riser Guidelines
Riser/Slot Numbers
Electrical
Mechanical
Source
Riser 0 - Slot 0
x8
x8
MCP55
Riser 0 - Slot 3
x8
x8
MCP55
Riser 1 - Slot 1
x8
x8
MCP55
Riser 1 - Slot 4
x8
x8
IO55
Riser 2 - Slot 2
x16
x16
IO55
Riser 2 - Slot 5
x4
x8
IO55
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...