Chapter 4
Servicing Motherboard Components
4-29
3. If necessary, review the PCIe Card Guidelines to plan your installation.
See
Section 4.5.1, “Sun Fire X4440 PCIe Card Guidelines” on page 4-25
for
additional information.
4. Remove the PCIe riser board.
See
Section 4.4, “Servicing PCIe Risers” on page 4-21
.
5. If the server has been continously used for an extended time, inspect the slot for
particles.
Clean the slot with filtered, compressed air, as required.
6. Remove the PCI filler panel. (
FIGURE 4-14
[1])
PCIe filler panels are located in the motherboard rear panel.
7. Insert the PCIe card into the correct slot on the PCIe riser board. [2]
8. Replace the PCIe riser. [3]
See
Section 4.4.2, “Installing a PCIe Riser” on page 4-23
.
a. Slide the riser back until it seats in its slot in the rear panel.
b. Tighten the captive No. 2 Phillips screw securing the riser to the
motherboard.
9. Replace the rear panel PCI crossbeam. [4]
a. Slide the crossbeam down over the PCIe risers.
b. Secure the PCI crossbeam is secured with two captive Phillips screws.
10. Connect any data cables required to the PCIe card.
Route data cables through the cable management arm.
11. Return the server to operation.
a. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
b. Slide the server into the rack.
See
Section 6.3, “Returning the Server to the Normal Rack Position” on
page 6-4
.
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-6
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-6
.
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...