Chapter 5
Servicing Infrastructure Boards and Components
5-31
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Remove the mezzanine tray.
See
Section 4.2.1, “Removing the Mezzanine Tray” on page 4-13
.
3. Remove the air duct.
See
Section 4.3.1, “Removing the Air Duct” on page 4-16
.
4. Remove the fan modules.
See
Section 3.5.4, “Removing a Fan Module” on page 3-13
.
5. Remove the fan power boards.
See
Section 5.1.1, “Removing a Fan Power Board” on page 5-2
.
6. Remove the mezzanine tray support bracket from the power supply bay wall.
7. Thread the PB end of the cables underneath the midwall, towards the drive
backplane.
a. Connect the connector labeled
PB 0, 1, 2, and 3
to the conector furthest from
the power supply.
b. Connect the connector labeled
PB 4, 5, 6, and 7
to the connector nearest to the
power supply.
8. Reinstall the fan boards, making sure the cable is not pinched.
The cable routes through the slot underneath of the fan boards.
9. Route the cable towards the power supply bay, and over the notch in the vertical
power supply unit backplane.
The cable then dips slightly to run underneath the ribs on the mezzanine tray
support bracket.
10. Reinstall the mezzanine tray support bracket.
Be careful not to pinch the cable.
11. Install the SAS HBA card in PCIe slot 0.
The lower card on the riser is closest to the power supply wall.
12. Install the connector labeled
MB 0, 1, 2, and 3
into the motherboard connector
labeled SATA 0.
Содержание Fire X4440
Страница 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Страница 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Страница 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Страница 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Страница 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 63: ...Chapter 3 Servicing Customer Replaceable Devices 3 23 FIGURE 3 16 Installing the DVD USB Module ...
Страница 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 68: ...4 4 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 1 Fault Remind Button Locations ...
Страница 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Страница 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Страница 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Страница 172: ...5 50 Sun Fire X4440 Server Service Manual September 2010 FIGURE 5 26 Converting Onboard SATA to HBA ...
Страница 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Страница 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...