Appendix A
External Connections
A-5
A.2
Alarms Port
The alarms service port is a male DB-15 (
lists the pinout
information.
FIGURE A-3
DB-15 (Male) Alarms Service Port Connector
TABLE A-2
Alarms Service Port Connector Pinout
Pin
Signal Name
Description
State
1
Not connected
2
Not connected
3
Not connected
4
Not connected
5
SYSTEM_NO
UNIX Running
Normally open
6
SYSTEM_NC
UNIX Running
Normally closed
7
SYSTEM_COM
UNIX Running
Common
8
ALARM1_NO
Alarm1
Normally open
9
ALARM1_NC
Alarm1
Normally closed
10
ALARM1_COM
Alarm1
Common
11
ALARM2_NO
Alarm2
Normally open
12
ALARM2_NC
Alarm2
Normally closed
13
ALARM2_COM
Alarm2
Common
14
Not connected
15
Not connected
8
1
9
15
ALARMS